Quantum-beat photoelectron-imaging spectroscopy of Xe in the VUV. Forbes, R., Makhija, V., Underwood, J. G., Stolow, A., Wilkinson, I., Hockett, P., & Lausten, R. Physical Review A, 97(6):063417, June, 2018.
Quantum-beat photoelectron-imaging spectroscopy of Xe in the VUV [link]Paper  doi  abstract   bibtex   
Time-resolved pump-probe measurements of Xe, pumped at 133\ nm and probed at 266\ nm, are presented. The pump pulse prepared a long-lived hyperfine wavepacket, in the Xe $}5p{^}5({^}2P{^}{\{}i̧rc{\}}{_}{\{}1/2{\}})6s{\ {}}{^}2[1/2]{^}{\{}i̧rc{\}}{_}1{$ manifold ($}E={$77185 cm$}{^}{\{}-1{\}}={$9.57 eV). The wavepacket was monitored via single-photon ionization, and photoelectron images measured. The images provide angle- and time-resolved data which, when obtained over a large time-window (900\ ps), constitute a precision quantum beat spectroscopy measurement of the hyperfine state splittings. Additionally, analysis of the full photoelectron image stack provides a quantum beat imaging modality, in which the Fourier components of the photoelectron images correlated with specific beat components can be obtained. This may also permit the extraction of isotope-resolved photoelectron images in the frequency domain, in cases where nuclear spins (hence beat components) can be uniquely assigned to specific isotopes (as herein), and also provides phase information. The information content of both raw, and inverted, image stacks is investigated, suggesting the utility of the Fourier analysis methodology in cases where images cannot be inverted.
@Article{Forbes2018,
  author        = {Forbes, Ruaridh and Makhija, Varun and Underwood, Jonathan G. and Stolow, Albert and Wilkinson, Iain and Hockett, Paul and Lausten, Rune},
  journal       = {Physical Review A},
  title         = {{Quantum-beat photoelectron-imaging spectroscopy of Xe in the VUV}},
  year          = {2018},
  issn          = {2469-9926},
  month         = jun,
  number        = {6},
  pages         = {063417},
  volume        = {97},
  abstract      = {Time-resolved pump-probe measurements of Xe, pumped at 133{\~{}}nm and probed at 266{\~{}}nm, are presented. The pump pulse prepared a long-lived hyperfine wavepacket, in the Xe {\$}5p{\^{}}5({\^{}}2P{\^{}}{\{}\backslashcirc{\}}{\_}{\{}1/2{\}})6s{\~{}}{\^{}}2[1/2]{\^{}}{\{}\backslashcirc{\}}{\_}1{\$} manifold ({\$}E={\$}77185 cm{\$}{\^{}}{\{}-1{\}}={\$}9.57 eV). The wavepacket was monitored via single-photon ionization, and photoelectron images measured. The images provide angle- and time-resolved data which, when obtained over a large time-window (900{\~{}}ps), constitute a precision quantum beat spectroscopy measurement of the hyperfine state splittings. Additionally, analysis of the full photoelectron image stack provides a quantum beat imaging modality, in which the Fourier components of the photoelectron images correlated with specific beat components can be obtained. This may also permit the extraction of isotope-resolved photoelectron images in the frequency domain, in cases where nuclear spins (hence beat components) can be uniquely assigned to specific isotopes (as herein), and also provides phase information. The information content of both raw, and inverted, image stacks is investigated, suggesting the utility of the Fourier analysis methodology in cases where images cannot be inverted.},
  archiveprefix = {arXiv},
  arxivid       = {1803.01081},
  doi           = {10.1103/PhysRevA.97.063417},
  eprint        = {1803.01081},
  groups        = {[paul:]},
  timestamp     = {2018.07.12},
  url           = {http://arxiv.org/abs/1803.01081},
}

Downloads: 0