Exploring new mass regions with the ISOLTRAP spectrometer. Beck, D., Arnes, F., Audi, G., Bollen, G., Kluge, H., J., Kohl, A., König, M., Martel, I., Lunney, D., Moore, R., B., Raimbault-Hartmann, H., De Saint Simon, M., Schark, E., Schwarz, S., & Szerypo, J. Hyperfine Interactions, 108(1-3):219-225, Kluwer Academic Publishers, 1997.
Exploring new mass regions with the ISOLTRAP spectrometer [link]Website  abstract   bibtex   
First direct mass measurements on rare earth isotopes around146Gd have been performed with the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. More than 40 isotopes of the elements Pr, Nd, Pm, Sm, Eu, Dy and Ho have been measured with an accuracy of typically 1 × 10-7. In the case of141Sm isomeric and ground state (ΔE = 175 keV) were resolved. Since isobaric contaminations are present in the ISOLDE beam, these measurements on rare earth isotopes became only possible after the installation of a new cooler trap which acts an isobar separator.
@article{
 title = {Exploring new mass regions with the ISOLTRAP spectrometer},
 type = {article},
 year = {1997},
 identifiers = {[object Object]},
 pages = {219-225},
 volume = {108},
 websites = {http://link.springer.com/10.1023/A:1012658628740},
 publisher = {Kluwer Academic Publishers},
 id = {6b6a6ff4-b59d-3e50-901e-a1985fc32c24},
 created = {2020-02-08T12:20:57.831Z},
 accessed = {2019-08-20},
 file_attached = {false},
 profile_id = {4aed738b-137b-3d29-9e3a-9ef895581cc9},
 group_id = {9c1e85b4-555e-34ef-a3a3-a6268514e8dc},
 last_modified = {2020-02-08T12:20:57.831Z},
 read = {false},
 starred = {false},
 authored = {false},
 confirmed = {false},
 hidden = {false},
 private_publication = {false},
 abstract = {First direct mass measurements on rare earth isotopes around146Gd have been performed with the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. More than 40 isotopes of the elements Pr, Nd, Pm, Sm, Eu, Dy and Ho have been measured with an accuracy of typically 1 × 10-7. In the case of141Sm isomeric and ground state (ΔE = 175 keV) were resolved. Since isobaric contaminations are present in the ISOLDE beam, these measurements on rare earth isotopes became only possible after the installation of a new cooler trap which acts an isobar separator.},
 bibtype = {article},
 author = {Beck, D. and Arnes, F. and Audi, G. and Bollen, G. and Kluge, H. J. and Kohl, A. and König, M. and Martel, I. and Lunney, D. and Moore, R. B. and Raimbault-Hartmann, H. and De Saint Simon, M. and Schark, E. and Schwarz, S. and Szerypo, J.},
 journal = {Hyperfine Interactions},
 number = {1-3}
}

Downloads: 0