Direct olive oil analysis by mass spectrometry: A comparison of different ambient ionization methods. Talanta, 180:168-175, 2018. cited By 35
Paper doi abstract bibtex Analytical methods based on ambient ionization mass spectrometry (AIMS) combine the classic outstanding performance of mass spectrometry in terms of sensitivity and selectivity along with convenient features related to the lack of sample workup required. In this work, the performance of different mass spectrometry-based methods has been assessed for the direct analyses of virgin olive oil for quality purposes. Two sets of experiments have been setup: (1) direct analysis of untreated olive oil using AIMS methods such as Low-Temperature Plasma Mass Spectrometry (LTP-MS) or paper spray mass spectrometry (PS-MS); or alternatively (2) the use of atmospheric pressure ionization (API) mass spectrometry by direct infusion of a diluted sample through either atmospheric pressure chemical ionization (APCI) or electrospray (ESI) ionization sources. The second strategy involved a minimum sample work-up consisting of a simple olive oil dilution (from 1:10 to 1:1000) with appropriate solvents, which originated critical carry over effects in ESI, making unreliable its use in routine; thus, ESI required the use of a liquid-liquid extraction to shift the measurement towards a specific part of the composition of the edible oil (i.e. polyphenol rich fraction or lipid/fatty acid profile). On the other hand, LTP-MS enabled direct undiluted mass analysis of olive oil. The use of PS-MS provided additional advantages such as an extended ionization coverage/molecular weight range (compared to LTP-MS) and the possibility to increase the ionization efficiency towards nonpolar compounds such as squalene through the formation of Ag+ adducts with carbon-carbon double bounds, an attractive feature to discriminate between oils with different degree of unsaturation. © 2017 Elsevier B.V.
Downloads: 0
{"_id":"eHtLnupdjCiypZSCP","bibbaseid":"anonymous-directoliveoilanalysisbymassspectrometryacomparisonofdifferentambientionizationmethods-2018","bibdata":{"bibtype":"article","type":"article","author":[{"propositions":[],"lastnames":["Lara-Ortega"],"firstnames":["F.J."],"suffixes":[]},{"propositions":[],"lastnames":["Beneito-Cambra"],"firstnames":["M."],"suffixes":[]},{"propositions":[],"lastnames":["Robles-Molina"],"firstnames":["J."],"suffixes":[]},{"propositions":[],"lastnames":["García-Reyes"],"firstnames":["J.F."],"suffixes":[]},{"propositions":[],"lastnames":["Gilbert-López"],"firstnames":["B."],"suffixes":[]},{"propositions":[],"lastnames":["Molina-Díaz"],"firstnames":["A."],"suffixes":[]}],"title":"Direct olive oil analysis by mass spectrometry: A comparison of different ambient ionization methods","journal":"Talanta","year":"2018","volume":"180","pages":"168-175","doi":"10.1016/j.talanta.2017.12.027","note":"cited By 35","url":"https://www.scopus.com/inward/record.uri?eid=2-s2.0-85038874945&doi=10.1016%2fj.talanta.2017.12.027&partnerID=40&md5=3ec644c736c9fe02338fb67e4b70a4bd","affiliation":"Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, 23071, Spain; Center for Advanced Studies in Olives Grove and Olive Oils (CEAOAO), Science and Technology Park GEOLIT, E-23620 Mengíbar, Jaén, Spain","abstract":"Analytical methods based on ambient ionization mass spectrometry (AIMS) combine the classic outstanding performance of mass spectrometry in terms of sensitivity and selectivity along with convenient features related to the lack of sample workup required. In this work, the performance of different mass spectrometry-based methods has been assessed for the direct analyses of virgin olive oil for quality purposes. Two sets of experiments have been setup: (1) direct analysis of untreated olive oil using AIMS methods such as Low-Temperature Plasma Mass Spectrometry (LTP-MS) or paper spray mass spectrometry (PS-MS); or alternatively (2) the use of atmospheric pressure ionization (API) mass spectrometry by direct infusion of a diluted sample through either atmospheric pressure chemical ionization (APCI) or electrospray (ESI) ionization sources. The second strategy involved a minimum sample work-up consisting of a simple olive oil dilution (from 1:10 to 1:1000) with appropriate solvents, which originated critical carry over effects in ESI, making unreliable its use in routine; thus, ESI required the use of a liquid-liquid extraction to shift the measurement towards a specific part of the composition of the edible oil (i.e. polyphenol rich fraction or lipid/fatty acid profile). On the other hand, LTP-MS enabled direct undiluted mass analysis of olive oil. The use of PS-MS provided additional advantages such as an extended ionization coverage/molecular weight range (compared to LTP-MS) and the possibility to increase the ionization efficiency towards nonpolar compounds such as squalene through the formation of Ag+ adducts with carbon-carbon double bounds, an attractive feature to discriminate between oils with different degree of unsaturation. © 2017 Elsevier B.V.","author_keywords":"Direct analysis; Low temperature plasma; Mass spectrometry; Olive oil; Paper spray","keywords":"Atmospheric chemistry; Atmospheric ionization; Atmospheric pressure; Carbon; Chemical analysis; Electrospray ionization; Mass spectrometry; Temperature, Ambient ionizations; Atmospheric pressure chemical ionization; Atmospheric pressure ionization; Degree of unsaturations; Direct analysis; Ionization efficiency; Liquid-liquid extraction; Low temperature plasmas, Olive oil, ion; olive oil; squalene; triacylglycerol, atmospheric pressure; chemistry; cold; comparative study; devices; electrospray mass spectrometry; equipment design; food analysis; liquid liquid extraction; mass spectrometry; procedures, Atmospheric Pressure; Cold Temperature; Equipment Design; Food Analysis; Ions; Liquid-Liquid Extraction; Mass Spectrometry; Olive Oil; Spectrometry, Mass, Electrospray Ionization; Squalene; Triglycerides","chemicals_cas":"olive oil, 8001-25-0; squalene, 111-02-4, 7683-64-9; Ions; Olive Oil; Squalene; Triglycerides","funding_details":"Junta de AndalucíaJunta de Andalucía, AGR-6066, FQM-2242","key":"Lara-Ortega2018168","id":"Lara-Ortega2018168","bibbaseid":"anonymous-directoliveoilanalysisbymassspectrometryacomparisonofdifferentambientionizationmethods-2018","role":"author","urls":{"Paper":"https://www.scopus.com/inward/record.uri?eid=2-s2.0-85038874945&doi=10.1016%2fj.talanta.2017.12.027&partnerID=40&md5=3ec644c736c9fe02338fb67e4b70a4bd"},"keyword":["Atmospheric chemistry; Atmospheric ionization; Atmospheric pressure; Carbon; Chemical analysis; Electrospray ionization; Mass spectrometry; Temperature","Ambient ionizations; Atmospheric pressure chemical ionization; Atmospheric pressure ionization; Degree of unsaturations; Direct analysis; Ionization efficiency; Liquid-liquid extraction; Low temperature plasmas","Olive oil","ion; olive oil; squalene; triacylglycerol","atmospheric pressure; chemistry; cold; comparative study; devices; electrospray mass spectrometry; equipment design; food analysis; liquid liquid extraction; mass spectrometry; procedures","Atmospheric Pressure; Cold Temperature; Equipment Design; Food Analysis; Ions; Liquid-Liquid Extraction; Mass Spectrometry; Olive Oil; Spectrometry","Mass","Electrospray Ionization; Squalene; Triglycerides"],"metadata":{"authorlinks":{}},"html":""},"bibtype":"article","biburl":"https://www.clecem.es/wp-content/uploads/2024/01/scopus.bib","dataSources":["z88YG74vvXjjYpRcn"],"keywords":["atmospheric chemistry; atmospheric ionization; atmospheric pressure; carbon; chemical analysis; electrospray ionization; mass spectrometry; temperature","ambient ionizations; atmospheric pressure chemical ionization; atmospheric pressure ionization; degree of unsaturations; direct analysis; ionization efficiency; liquid-liquid extraction; low temperature plasmas","olive oil","ion; olive oil; squalene; triacylglycerol","atmospheric pressure; chemistry; cold; comparative study; devices; electrospray mass spectrometry; equipment design; food analysis; liquid liquid extraction; mass spectrometry; procedures","atmospheric pressure; cold temperature; equipment design; food analysis; ions; liquid-liquid extraction; mass spectrometry; olive oil; spectrometry","mass","electrospray ionization; squalene; triglycerides"],"search_terms":["direct","olive","oil","analysis","mass","spectrometry","comparison","different","ambient","ionization","methods"],"title":"Direct olive oil analysis by mass spectrometry: A comparison of different ambient ionization methods","year":2018}