Removal of phosphate from aqueous solutions by electro-coagulation. Bektas, N., Akbulut, H., Inan, H., & Dimoglo, A. JOURNAL OF HAZARDOUS MATERIALS, 106(2-3):101-105, 2004. abstract bibtex The aim of this paper was to investigate the feasibility of the removal
of phosphate from aqueous solution by electro-coagulation (EC). The
current density (CD) between 2.5 and 10 mA cm(-2) and duration in the
limits of 5-20 min were tried for different concentrations. In order to
determine optimal operating conditions, the EC process used for the
phosphate removal was examined in dependence with the CD, initial
concentrations and time. The results of the experimental batch
processing showed high effectiveness of the EC method in removing
phosphate from aqueous solutions. 2003 (C) Elsevier B.V. All rights
reserved.
@article{
title = {Removal of phosphate from aqueous solutions by electro-coagulation},
type = {article},
year = {2004},
identifiers = {[object Object]},
pages = {101-105},
volume = {106},
id = {d5595fde-3169-3eaf-ba69-039e0237fd9f},
created = {2016-04-28T08:46:11.000Z},
file_attached = {false},
profile_id = {dce7c6b2-57cf-350f-b364-3e8ed99bb344},
group_id = {bfd80d76-e42d-36f1-b5b9-353e1a47eb95},
last_modified = {2016-04-28T08:46:11.000Z},
read = {false},
starred = {false},
authored = {false},
confirmed = {true},
hidden = {false},
citation_key = {ISI:000189111700004},
source_type = {article},
abstract = {The aim of this paper was to investigate the feasibility of the removal
of phosphate from aqueous solution by electro-coagulation (EC). The
current density (CD) between 2.5 and 10 mA cm(-2) and duration in the
limits of 5-20 min were tried for different concentrations. In order to
determine optimal operating conditions, the EC process used for the
phosphate removal was examined in dependence with the CD, initial
concentrations and time. The results of the experimental batch
processing showed high effectiveness of the EC method in removing
phosphate from aqueous solutions. 2003 (C) Elsevier B.V. All rights
reserved.},
bibtype = {article},
author = {Bektas, N and Akbulut, H and Inan, H and Dimoglo, A},
journal = {JOURNAL OF HAZARDOUS MATERIALS},
number = {2-3}
}
Downloads: 0
{"_id":"sErxKB8L3GKrY9WYk","bibbaseid":"bektas-akbulut-inan-dimoglo-removalofphosphatefromaqueoussolutionsbyelectrocoagulation-2004","downloads":0,"creationDate":"2016-04-28T08:42:22.742Z","title":"Removal of phosphate from aqueous solutions by electro-coagulation","author_short":["Bektas, N.","Akbulut, H.","Inan, H.","Dimoglo, A."],"year":2004,"bibtype":"article","biburl":null,"bibdata":{"title":"Removal of phosphate from aqueous solutions by electro-coagulation","type":"article","year":"2004","identifiers":"[object Object]","pages":"101-105","volume":"106","id":"d5595fde-3169-3eaf-ba69-039e0237fd9f","created":"2016-04-28T08:46:11.000Z","file_attached":false,"profile_id":"dce7c6b2-57cf-350f-b364-3e8ed99bb344","group_id":"bfd80d76-e42d-36f1-b5b9-353e1a47eb95","last_modified":"2016-04-28T08:46:11.000Z","read":false,"starred":false,"authored":false,"confirmed":"true","hidden":false,"citation_key":"ISI:000189111700004","source_type":"article","abstract":"The aim of this paper was to investigate the feasibility of the removal\nof phosphate from aqueous solution by electro-coagulation (EC). The\ncurrent density (CD) between 2.5 and 10 mA cm(-2) and duration in the\nlimits of 5-20 min were tried for different concentrations. In order to\ndetermine optimal operating conditions, the EC process used for the\nphosphate removal was examined in dependence with the CD, initial\nconcentrations and time. The results of the experimental batch\nprocessing showed high effectiveness of the EC method in removing\nphosphate from aqueous solutions. 2003 (C) Elsevier B.V. All rights\nreserved.","bibtype":"article","author":"Bektas, N and Akbulut, H and Inan, H and Dimoglo, A","journal":"JOURNAL OF HAZARDOUS MATERIALS","number":"2-3","bibtex":"@article{\n title = {Removal of phosphate from aqueous solutions by electro-coagulation},\n type = {article},\n year = {2004},\n identifiers = {[object Object]},\n pages = {101-105},\n volume = {106},\n id = {d5595fde-3169-3eaf-ba69-039e0237fd9f},\n created = {2016-04-28T08:46:11.000Z},\n file_attached = {false},\n profile_id = {dce7c6b2-57cf-350f-b364-3e8ed99bb344},\n group_id = {bfd80d76-e42d-36f1-b5b9-353e1a47eb95},\n last_modified = {2016-04-28T08:46:11.000Z},\n read = {false},\n starred = {false},\n authored = {false},\n confirmed = {true},\n hidden = {false},\n citation_key = {ISI:000189111700004},\n source_type = {article},\n abstract = {The aim of this paper was to investigate the feasibility of the removal\nof phosphate from aqueous solution by electro-coagulation (EC). The\ncurrent density (CD) between 2.5 and 10 mA cm(-2) and duration in the\nlimits of 5-20 min were tried for different concentrations. In order to\ndetermine optimal operating conditions, the EC process used for the\nphosphate removal was examined in dependence with the CD, initial\nconcentrations and time. The results of the experimental batch\nprocessing showed high effectiveness of the EC method in removing\nphosphate from aqueous solutions. 2003 (C) Elsevier B.V. All rights\nreserved.},\n bibtype = {article},\n author = {Bektas, N and Akbulut, H and Inan, H and Dimoglo, A},\n journal = {JOURNAL OF HAZARDOUS MATERIALS},\n number = {2-3}\n}","author_short":["Bektas, N.","Akbulut, H.","Inan, H.","Dimoglo, A."],"bibbaseid":"bektas-akbulut-inan-dimoglo-removalofphosphatefromaqueoussolutionsbyelectrocoagulation-2004","role":"author","urls":{},"downloads":0,"html":""},"search_terms":["removal","phosphate","aqueous","solutions","electro","coagulation","bektas","akbulut","inan","dimoglo"],"keywords":[],"authorIDs":[]}