Artifacts in T1??-weighted imaging: Correction with a self-compensating spin-locking pulse. Charagundla, S. R., Borthakur, A., Leigh, J. S., & Reddy, R. Journal of Magnetic Resonance, 162(1):113--121, 2003. doi abstract bibtex Significant artifacts arise in T1??-weighted imaging when nutation angles suffer small deviations from their expected values. These artifacts vary with spin-locking time and amplitude, severely limiting attempts to perform quantitative imaging or measurement of T1?? relaxation times. A theoretical model explaining the origin of these artifacts is presented in the context of a T1??-prepared fast spin-echo imaging sequence. Experimentally obtained artifacts are compared to those predicted by theory and related to B1 inhomogeneity. Finally, a "self-compensating" spin-locking preparatory pulse cluster is presented, in which the second half of the spin-locking pulse is phase-shifted by 180??. Use of this pulse sequence maintains relatively uniform signal intensity despite large variations in flip angle, greatly reducing artifacts in T1??-weighted imaging. ?? 2003 Elsevier Science (USA). All rights reserved.
@article{ Charagundla2003,
abstract = {Significant artifacts arise in T1??-weighted imaging when nutation angles suffer small deviations from their expected values. These artifacts vary with spin-locking time and amplitude, severely limiting attempts to perform quantitative imaging or measurement of T1?? relaxation times. A theoretical model explaining the origin of these artifacts is presented in the context of a T1??-prepared fast spin-echo imaging sequence. Experimentally obtained artifacts are compared to those predicted by theory and related to B1 inhomogeneity. Finally, a "self-compensating" spin-locking preparatory pulse cluster is presented, in which the second half of the spin-locking pulse is phase-shifted by 180??. Use of this pulse sequence maintains relatively uniform signal intensity despite large variations in flip angle, greatly reducing artifacts in T1??-weighted imaging. ?? 2003 Elsevier Science (USA). All rights reserved.},
author = {Charagundla, Sridhar R. and Borthakur, Arijitt and Leigh, John S. and Reddy, Ravinder},
doi = {10.1016/S1090-7807(02)00197-0},
file = {:home/jk636/c/public_html/shared/papers/T1rho Background_Science/Charagundla_JMR_2002.pdf:pdf},
isbn = {1090-7807 (Print)$\backslash$n1090-7807 (Linking)},
issn = {10907807},
journal = {Journal of Magnetic Resonance},
keywords = {Artifacts,B1,MRI,Rotary echo,T1??},
number = {1},
pages = {113--121},
pmid = {12762988},
title = {{Artifacts in T1??-weighted imaging: Correction with a self-compensating spin-locking pulse}},
volume = {162},
year = {2003}
}
Downloads: 0
{"_id":"8tNyqSPbPWDsArDhj","bibbaseid":"charagundla-borthakur-leigh-reddy-artifactsint1weightedimagingcorrectionwithaselfcompensatingspinlockingpulse-2003","downloads":0,"creationDate":"2015-04-02T14:52:01.343Z","title":"Artifacts in T1??-weighted imaging: Correction with a self-compensating spin-locking pulse","author_short":["Charagundla, S.<nbsp>R.","Borthakur, A.","Leigh, J.<nbsp>S.","Reddy, R."],"year":2003,"bibtype":"article","biburl":"http://www.physics.utah.edu/~jkaggie/collection.bib","bibdata":{"abstract":"Significant artifacts arise in T1??-weighted imaging when nutation angles suffer small deviations from their expected values. These artifacts vary with spin-locking time and amplitude, severely limiting attempts to perform quantitative imaging or measurement of T1?? relaxation times. A theoretical model explaining the origin of these artifacts is presented in the context of a T1??-prepared fast spin-echo imaging sequence. Experimentally obtained artifacts are compared to those predicted by theory and related to B1 inhomogeneity. Finally, a \"self-compensating\" spin-locking preparatory pulse cluster is presented, in which the second half of the spin-locking pulse is phase-shifted by 180??. Use of this pulse sequence maintains relatively uniform signal intensity despite large variations in flip angle, greatly reducing artifacts in T1??-weighted imaging. ?? 2003 Elsevier Science (USA). All rights reserved.","author":["Charagundla, Sridhar R.","Borthakur, Arijitt","Leigh, John S.","Reddy, Ravinder"],"author_short":["Charagundla, S.<nbsp>R.","Borthakur, A.","Leigh, J.<nbsp>S.","Reddy, R."],"bibtex":"@article{ Charagundla2003,\n abstract = {Significant artifacts arise in T1??-weighted imaging when nutation angles suffer small deviations from their expected values. These artifacts vary with spin-locking time and amplitude, severely limiting attempts to perform quantitative imaging or measurement of T1?? relaxation times. A theoretical model explaining the origin of these artifacts is presented in the context of a T1??-prepared fast spin-echo imaging sequence. Experimentally obtained artifacts are compared to those predicted by theory and related to B1 inhomogeneity. Finally, a \"self-compensating\" spin-locking preparatory pulse cluster is presented, in which the second half of the spin-locking pulse is phase-shifted by 180??. Use of this pulse sequence maintains relatively uniform signal intensity despite large variations in flip angle, greatly reducing artifacts in T1??-weighted imaging. ?? 2003 Elsevier Science (USA). All rights reserved.},\n author = {Charagundla, Sridhar R. and Borthakur, Arijitt and Leigh, John S. and Reddy, Ravinder},\n doi = {10.1016/S1090-7807(02)00197-0},\n file = {:home/jk636/c/public_html/shared/papers/T1rho Background_Science/Charagundla_JMR_2002.pdf:pdf},\n isbn = {1090-7807 (Print)$\\backslash$n1090-7807 (Linking)},\n issn = {10907807},\n journal = {Journal of Magnetic Resonance},\n keywords = {Artifacts,B1,MRI,Rotary echo,T1??},\n number = {1},\n pages = {113--121},\n pmid = {12762988},\n title = {{Artifacts in T1??-weighted imaging: Correction with a self-compensating spin-locking pulse}},\n volume = {162},\n year = {2003}\n}","bibtype":"article","doi":"10.1016/S1090-7807(02)00197-0","file":":home/jk636/c/public_html/shared/papers/T1rho Background_Science/Charagundla_JMR_2002.pdf:pdf","id":"Charagundla2003","isbn":"1090-7807 (Print)$\\backslash$n1090-7807 (Linking)","issn":"10907807","journal":"Journal of Magnetic Resonance","key":"Charagundla2003","keywords":"Artifacts,B1,MRI,Rotary echo,T1??","number":"1","pages":"113--121","pmid":"12762988","title":"Artifacts in T1??-weighted imaging: Correction with a self-compensating spin-locking pulse","type":"article","volume":"162","year":"2003","bibbaseid":"charagundla-borthakur-leigh-reddy-artifactsint1weightedimagingcorrectionwithaselfcompensatingspinlockingpulse-2003","role":"author","urls":{},"keyword":["Artifacts","B1","MRI","Rotary echo","T1??"],"downloads":0},"search_terms":["artifacts","weighted","imaging","correction","self","compensating","spin","locking","pulse","charagundla","borthakur","leigh","reddy"],"keywords":["artifacts","b1","mri","rotary echo","t1??"],"authorIDs":[],"dataSources":["QJ7WTnmEn4pQk3aNw"]}