Effects of different concentrations of anticoagulant on the in vitro characteristics of autologous whole blood. Cober, N, Lacasse, M, Bart, B, & Rock, G Transfusion, 41(12):1606–1609, December, 2001.
Effects of different concentrations of anticoagulant on the in vitro characteristics of autologous whole blood [link]Paper  abstract   bibtex   
BACKGROUND Routinely, 450 mL of blood is collected into 63 mL of CPDA-1, for a final anticoagulant:blood ratio of approximately 1:7 in a whole-blood autologous unit. If less than 300 mL of blood is to be collected, the AABB standards suggest that there should be a proportionate decrease in anticoagulant. Data from an autologous blood program showed a range in volume from 92 mL to 667 mL per bag, which reflects an anticoagulant:blood ratio of 2:1 to 1:10. STUDY DESIGN AND METHODS To determine the effects of these ratios on the in vitro function of RBCs at various anticoagulant ratios, blood was collected into different amounts of anticoagulant, and various measurements were made during storage. RESULTS The number of RBCs and the MCV remained constant over time, regardless of the anticoagulant dilution used. Plasma free Hb increased with time with all dilutions. At a 1:2 ratio, it rose from 734 mg per L on Day 1 to 1805 mg per L on Day 35, and at 1:8, it was 355 mg per L for Day 1 and 854 mg per L on Day 35. Plasma sodium decreased and the potassium increased over time with all dilutions. From Day 1 to Day 35, there was a nine-fold increase in potassium at both the 1:2 and 1:8 dilutions (2.4 to 22.9 mmol/L, 3.2 to 29.6 mmol/L, respectively). The LDH increased over time and the pH decreased in all of the dilutions. Osmotic fragility remained constant at the 1:8 dilution but decreased at all of the other dilutions with storage, with 44-percent fragility on Day 35 at the 1:2 ratio. The WBC and platelet counts decreased consistently over time. Overall, 1 percent of the autologous units were below the cutoff volume of 300 mL at which an adjustment of the anticoagulant volume is required. CONCLUSION Plasma Hb and plasma potassium concentrations are considerably higher in low-volume units, which indicates that deviation from standard collection procedures is deleterious to RBCs.
@article{cober_effects_2001,
	title = {Effects of different concentrations of anticoagulant on the in vitro characteristics of autologous whole blood},
	volume = {41},
	issn = {0041-1132},
	url = {http://www.ncbi.nlm.nih.gov/pubmed/11778079},
	abstract = {BACKGROUND

Routinely, 450 mL of blood is collected into 63 mL of CPDA-1, for a final anticoagulant:blood ratio of approximately 1:7 in a whole-blood autologous unit. If less than 300 mL of blood is to be collected, the AABB standards suggest that there should be a proportionate decrease in anticoagulant. Data from an autologous blood program showed a range in volume from 92 mL to 667 mL per bag, which reflects an anticoagulant:blood ratio of 2:1 to 1:10.


STUDY DESIGN AND METHODS

To determine the effects of these ratios on the in vitro function of RBCs at various anticoagulant ratios, blood was collected into different amounts of anticoagulant, and various measurements were made during storage.


RESULTS

The number of RBCs and the MCV remained constant over time, regardless of the anticoagulant dilution used. Plasma free Hb increased with time with all dilutions. At a 1:2 ratio, it rose from 734 mg per L on Day 1 to 1805 mg per L on Day 35, and at 1:8, it was 355 mg per L for Day 1 and 854 mg per L on Day 35. Plasma sodium decreased and the potassium increased over time with all dilutions. From Day 1 to Day 35, there was a nine-fold increase in potassium at both the 1:2 and 1:8 dilutions (2.4 to 22.9 mmol/L, 3.2 to 29.6 mmol/L, respectively). The LDH increased over time and the pH decreased in all of the dilutions. Osmotic fragility remained constant at the 1:8 dilution but decreased at all of the other dilutions with storage, with 44-percent fragility on Day 35 at the 1:2 ratio. The WBC and platelet counts decreased consistently over time. Overall, 1 percent of the autologous units were below the cutoff volume of 300 mL at which an adjustment of the anticoagulant volume is required.


CONCLUSION

Plasma Hb and plasma potassium concentrations are considerably higher in low-volume units, which indicates that deviation from standard collection procedures is deleterious to RBCs.},
	number = {12},
	urldate = {2012-05-22TZ},
	journal = {Transfusion},
	author = {Cober, N and Lacasse, M and Bart, B and Rock, G},
	month = dec,
	year = {2001},
	pmid = {11778079},
	keywords = {Adenine, Anticoagulants, Blood Cell Count, Blood Specimen Collection, Blood Transfusion, Autologous, Citrates, Dose-Response Relationship, Drug, Erythrocyte Indices, Erythrocytes, Glucose, Hemoglobins, Humans, L-Lactate Dehydrogenase, Phosphates, Potassium, Sodium, Time Factors},
	pages = {1606--1609}
}