Development and exploration of a new methodology for the fitting and analysis of XAS data. Delgado-Jaime, M., U. & Kennepohl, P. J. Synchrotron Rad., 17(1):119-28, International Union of Crystallography, 1, 2010. Paper Website doi abstract bibtex A new data analysis methodology for X-ray absorption near-edge spectroscopy (XANES) is introduced and tested using several examples. The methodology has been implemented within the context of a new Matlab-based program discussed in a companion related article [Delgado-Jaime et al. (2010), J. Synchrotron Rad. 17, 132-137]. The approach makes use of a Monte Carlo search method to seek appropriate starting points for a fit model, allowing for the generation of a large number of independent fits with minimal user-induced bias. The applicability of this methodology is tested using various data sets on the Cl K-edge XAS data for tetragonal CuCl(4)(2-), a common reference compound used for calibration and covalency estimation in M-Cl bonds. A new background model function that effectively blends together background profiles with spectral features is an important component of the discussed methodology. The development of a robust evaluation function to fit multiple-edge data is discussed and the implications regarding standard approaches to data analysis are discussed and explored within these examples.
@article{
title = {Development and exploration of a new methodology for the fitting and analysis of XAS data.},
type = {article},
year = {2010},
keywords = {Method Development,X-ray Absorption Spectroscopy},
pages = {119-28},
volume = {17},
websites = {http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=2816928&tool=pmcentrez&rendertype=abstract,http://dx.doi.org/10.1107/S090904950904655X},
month = {1},
publisher = {International Union of Crystallography},
id = {a3654522-ed2a-3167-91f1-ad6b14e78153},
created = {2017-09-06T15:15:22.260Z},
accessed = {2012-10-06},
file_attached = {true},
profile_id = {8c5f55f8-b69e-30e2-981b-01f0d567bbfe},
last_modified = {2020-04-29T22:46:48.212Z},
read = {true},
starred = {true},
authored = {true},
confirmed = {true},
hidden = {false},
citation_key = {Delgado-Jaime2010},
source_type = {Journal Article},
notes = {<b>From Duplicate 2 ( <i>Development and exploration of a new methodology for the fitting and analysis of XAS data.</i> - Delgado-Jaime, Mario Ulises; Kennepohl, Pierre )<br/></b><br/><b>From Duplicate 1 ( <i>Development and exploration of a new methodology for the fitting and analysis of XAS data</i> - Delgado-Jaime, Mario Ulises; Kennepohl, Pierre )<br/></b><br/><b>From Duplicate 1 ( <i>Development and exploration of a new methodology for the fitting and analysis of XAS data</i> - Delgado-Jaime, M U; Kennepohl, Pierre )<br/></b>},
folder_uuids = {51dd54b6-3357-45f2-ac25-d0a70ed27d18,e286fe6d-1c93-4648-bac6-84acad56f4e5,ebbabfbd-939b-434c-8a89-bba932203a0b},
private_publication = {false},
abstract = {A new data analysis methodology for X-ray absorption near-edge spectroscopy (XANES) is introduced and tested using several examples. The methodology has been implemented within the context of a new Matlab-based program discussed in a companion related article [Delgado-Jaime et al. (2010), J. Synchrotron Rad. 17, 132-137]. The approach makes use of a Monte Carlo search method to seek appropriate starting points for a fit model, allowing for the generation of a large number of independent fits with minimal user-induced bias. The applicability of this methodology is tested using various data sets on the Cl K-edge XAS data for tetragonal CuCl(4)(2-), a common reference compound used for calibration and covalency estimation in M-Cl bonds. A new background model function that effectively blends together background profiles with spectral features is an important component of the discussed methodology. The development of a robust evaluation function to fit multiple-edge data is discussed and the implications regarding standard approaches to data analysis are discussed and explored within these examples.},
bibtype = {article},
author = {Delgado-Jaime, Mario Ulises and Kennepohl, Pierre},
doi = {10.1107/S090904950904655X},
journal = {J. Synchrotron Rad.},
number = {1}
}
Downloads: 0
{"_id":"YqHELEeoB7ZkCR6mw","authorIDs":["3iLerqnFcxCPMtJpn","4c6QnidJqyh8QxqkX","549f69158e3bca5f370014e6","5de7ed0bc8f9f6df010001e4","5de839c88cf0fbde0100006d","5deacdf2cd660bde01000195","5debd29aca1cdddf01000146","5df7dc76dc100cde010000ff","5e042bf8c51eb3de0100007b","5e07c8ccea5f0bdf010000cf","5e0dc56cc7ca67df01000115","5e0ec889b68da9de01000034","5e0f7abf99975cde0100009e","5e10afd9cfb06ddf0100006d","5e1177267da100de0100012f","5e13d054280ddede0100016e","5e164e4428f1c0de0100031d","5e1693f8da4561de0100001f","5e177475cf35a4de01000031","5e1a947969523cde01000099","5e257428f58a5cde010000f1","5e2882d967e11edf010000ac","5e28f4bc41639df301000044","5e2e93568d5204de0100007e","5e31e94fbba4d0de01000241","5e326d5e5633c9de010000a3","5e342fca41f782de0100012d","5e35488dba591ddf0100008c","5e3665ad4b25bbf2010000d2","5e382dc30691b8de010001ff","5e3c4312c798e0de01000034","5e46844d71278bde010000cc","5e4eb15264b624de010001a8","5e4f912b42a908de010000f4","5e4fbd2d2c51e8de0100008d","5e5d63ddad47bcde01000122","5e5f86ed8d89c5de0100002e","5e5fd8e65241b5de0100001c","5e60ecfe839e59df01000140","5e61652b417d19de01000061","5e64d2ac0b8008df01000036","5e6741214d24a6df01000086","5e676b211dcaf4de010001ef","5e67802710be53de010000fe","5e68480a9cef79de01000273","5e68d91fae547ede010002af","5e69ce636423dfde010001a0","5e6b12e986bf9cde01000035","5e6b62aac024f9de01000010","5e6b9bf038517edf0100001b","79eiZqbXtAgB2qPwQ","7KTqYg8mwkZFhEzQ3","8M6CKnvXwvJZjw5rQ","8ZH5wCb244dTyjZTo","8gLLyGmGk6zrBNnSW","93wznsAiG6N6RWh3W","BdW2bNumN7KSubzZi","Brx9MCCWjaRcQLgmv","BunZ7u5vo6YP89dqC","CdmkqgCC7YQ3nCxbq","DNPrMfAuXetAfDs8R","E5dirXnhp3dj3aHkh","Fj7MuNTuEZrfjfxxi","HJ3Zeg39qQTmYHYt6","JnXN6mSgNQkfpmqTs","KLFz9Quyco9WRMzEo","MQPkCA7hCG5nHRDGK","MvxLkRFmWAmFzJ62x","NLLPFwcypsnqCdjtt","NgvWrQNZ8WSMvaySr","Qu6vBYRGk4HxjEQHP","RLApear4PKw8oDouR","S5uha8vZYCJgdy3wz","SrePPBjyQrYFJYWuq","TGJLqTRjTSCvjnKnM","TLPpMRduCgvt23KNA","ThXjmMxsKShGXGo9R","WCpGFZGKoopYdccrA","WkmF3PHxRiTFvpvMu","X3CoQQujbB6uEfeCq","XKcJSHf8DcpdPnfNm","XmtnqTvJBkZkvLBZP","YfXHeLKqBXYYzPAww","Zsrup8X5fqoNSkFPe","bHfLw2QkQGko4KjYg","cGwiLTEeZWEYwb88s","cqKH7BXTaAZGZDGzc","eDEjrBSoXdYAJegvm","ev4vmj6dMZpbEWwmy","fKj3TXX3ietf3qGt8","fM3TRWpPB6oRA8rB9","i4ftws6i5ecsWkmYD","k4yef9HxWgNCdW8b3","mReJFExBwnFax3ALu","mZCESDX4P5jLi3pce","nm4T2AcjanPHL4Szj","oaugrfPtDqADRQgJ4","ofGYJBrWWZQYsEGFR","pKG2zHMNxFQDkZHyb","rhhh4xdaNHz94oEm2","rrvwjEikXmbdXZkGx","tCt2KazanazJ3yQzz","uGy4Ag92HDCxNJkCo","vdvk9eCQyAxmSxLqs","xeyEua6SaCWFan2H4"],"author_short":["Delgado-Jaime, M., U.","Kennepohl, P."],"bibbaseid":"delgadojaime-kennepohl-developmentandexplorationofanewmethodologyforthefittingandanalysisofxasdata-2010","bibdata":{"title":"Development and exploration of a new methodology for the fitting and analysis of XAS data.","type":"article","year":"2010","keywords":"Method Development,X-ray Absorption Spectroscopy","pages":"119-28","volume":"17","websites":"http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=2816928&tool=pmcentrez&rendertype=abstract,http://dx.doi.org/10.1107/S090904950904655X","month":"1","publisher":"International Union of Crystallography","id":"a3654522-ed2a-3167-91f1-ad6b14e78153","created":"2017-09-06T15:15:22.260Z","accessed":"2012-10-06","file_attached":"true","profile_id":"8c5f55f8-b69e-30e2-981b-01f0d567bbfe","last_modified":"2020-04-29T22:46:48.212Z","read":"true","starred":"true","authored":"true","confirmed":"true","hidden":false,"citation_key":"Delgado-Jaime2010","source_type":"Journal Article","notes":"<b>From Duplicate 2 ( <i>Development and exploration of a new methodology for the fitting and analysis of XAS data.</i> - Delgado-Jaime, Mario Ulises; Kennepohl, Pierre )<br/></b><br/><b>From Duplicate 1 ( <i>Development and exploration of a new methodology for the fitting and analysis of XAS data</i> - Delgado-Jaime, Mario Ulises; Kennepohl, Pierre )<br/></b><br/><b>From Duplicate 1 ( <i>Development and exploration of a new methodology for the fitting and analysis of XAS data</i> - Delgado-Jaime, M U; Kennepohl, Pierre )<br/></b>","folder_uuids":"51dd54b6-3357-45f2-ac25-d0a70ed27d18,e286fe6d-1c93-4648-bac6-84acad56f4e5,ebbabfbd-939b-434c-8a89-bba932203a0b","private_publication":false,"abstract":"A new data analysis methodology for X-ray absorption near-edge spectroscopy (XANES) is introduced and tested using several examples. The methodology has been implemented within the context of a new Matlab-based program discussed in a companion related article [Delgado-Jaime et al. (2010), J. Synchrotron Rad. 17, 132-137]. The approach makes use of a Monte Carlo search method to seek appropriate starting points for a fit model, allowing for the generation of a large number of independent fits with minimal user-induced bias. The applicability of this methodology is tested using various data sets on the Cl K-edge XAS data for tetragonal CuCl(4)(2-), a common reference compound used for calibration and covalency estimation in M-Cl bonds. A new background model function that effectively blends together background profiles with spectral features is an important component of the discussed methodology. The development of a robust evaluation function to fit multiple-edge data is discussed and the implications regarding standard approaches to data analysis are discussed and explored within these examples.","bibtype":"article","author":"Delgado-Jaime, Mario Ulises and Kennepohl, Pierre","doi":"10.1107/S090904950904655X","journal":"J. Synchrotron Rad.","number":"1","bibtex":"@article{\n title = {Development and exploration of a new methodology for the fitting and analysis of XAS data.},\n type = {article},\n year = {2010},\n keywords = {Method Development,X-ray Absorption Spectroscopy},\n pages = {119-28},\n volume = {17},\n websites = {http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=2816928&tool=pmcentrez&rendertype=abstract,http://dx.doi.org/10.1107/S090904950904655X},\n month = {1},\n publisher = {International Union of Crystallography},\n id = {a3654522-ed2a-3167-91f1-ad6b14e78153},\n created = {2017-09-06T15:15:22.260Z},\n accessed = {2012-10-06},\n file_attached = {true},\n profile_id = {8c5f55f8-b69e-30e2-981b-01f0d567bbfe},\n last_modified = {2020-04-29T22:46:48.212Z},\n read = {true},\n starred = {true},\n authored = {true},\n confirmed = {true},\n hidden = {false},\n citation_key = {Delgado-Jaime2010},\n source_type = {Journal Article},\n notes = {<b>From Duplicate 2 ( <i>Development and exploration of a new methodology for the fitting and analysis of XAS data.</i> - Delgado-Jaime, Mario Ulises; Kennepohl, Pierre )<br/></b><br/><b>From Duplicate 1 ( <i>Development and exploration of a new methodology for the fitting and analysis of XAS data</i> - Delgado-Jaime, Mario Ulises; Kennepohl, Pierre )<br/></b><br/><b>From Duplicate 1 ( <i>Development and exploration of a new methodology for the fitting and analysis of XAS data</i> - Delgado-Jaime, M U; Kennepohl, Pierre )<br/></b>},\n folder_uuids = {51dd54b6-3357-45f2-ac25-d0a70ed27d18,e286fe6d-1c93-4648-bac6-84acad56f4e5,ebbabfbd-939b-434c-8a89-bba932203a0b},\n private_publication = {false},\n abstract = {A new data analysis methodology for X-ray absorption near-edge spectroscopy (XANES) is introduced and tested using several examples. The methodology has been implemented within the context of a new Matlab-based program discussed in a companion related article [Delgado-Jaime et al. (2010), J. Synchrotron Rad. 17, 132-137]. The approach makes use of a Monte Carlo search method to seek appropriate starting points for a fit model, allowing for the generation of a large number of independent fits with minimal user-induced bias. The applicability of this methodology is tested using various data sets on the Cl K-edge XAS data for tetragonal CuCl(4)(2-), a common reference compound used for calibration and covalency estimation in M-Cl bonds. A new background model function that effectively blends together background profiles with spectral features is an important component of the discussed methodology. The development of a robust evaluation function to fit multiple-edge data is discussed and the implications regarding standard approaches to data analysis are discussed and explored within these examples.},\n bibtype = {article},\n author = {Delgado-Jaime, Mario Ulises and Kennepohl, Pierre},\n doi = {10.1107/S090904950904655X},\n journal = {J. Synchrotron Rad.},\n number = {1}\n}","author_short":["Delgado-Jaime, M., U.","Kennepohl, P."],"urls":{"Paper":"https://bibbase.org/service/mendeley/8c5f55f8-b69e-30e2-981b-01f0d567bbfe/file/5d704021-6a4a-90a3-50a9-44a56a6c3289/2010___J_Synchrotron_Rad___Delgado_Jaime_Kennepohl___Development_and_exploration_of_a_new_methodology_for_the_fitting_an.pdf.pdf","Website":"http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=2816928&tool=pmcentrez&rendertype=abstract,http://dx.doi.org/10.1107/S090904950904655X"},"biburl":"https://bibbase.org/service/mendeley/8c5f55f8-b69e-30e2-981b-01f0d567bbfe","bibbaseid":"delgadojaime-kennepohl-developmentandexplorationofanewmethodologyforthefittingandanalysisofxasdata-2010","role":"author","keyword":["Method Development","X-ray Absorption Spectroscopy"],"metadata":{"authorlinks":{"kennepohl, p":"https://bibbase.org/service/mendeley/8c5f55f8-b69e-30e2-981b-01f0d567bbfe"}},"downloads":0},"bibtype":"article","biburl":"https://bibbase.org/service/mendeley/8c5f55f8-b69e-30e2-981b-01f0d567bbfe","creationDate":"2014-12-28T02:21:10.383Z","downloads":0,"keywords":["method development","x-ray absorption spectroscopy"],"search_terms":["development","exploration","new","methodology","fitting","analysis","xas","data","delgado-jaime","kennepohl"],"title":"Development and exploration of a new methodology for the fitting and analysis of XAS data.","year":2010,"dataSources":["MwHF28s95RpwxtWh3","ya2CyA73rpZseyrZ8","2252seNhipfTmjEBQ"]}