A wavelet-based 128-bit key generator using electrocardiogram signals. Garcia-Baleon, H., A., Alarcon-Aquino, V., & Starostenko, O. In 2009 52nd IEEE International Midwest Symposium on Circuits and Systems, pages 644-647, 8, 2009. IEEE. Website doi abstract bibtex In this paper, we present a wavelet-based 128-bit key generator using electrocardiogram (ECG) signals. The key generator comprises two independent stages, namely, enrollment and verification-generation. In the latter, an algorithm for determining the keys is also proposed. This work is based on the uniqueness and quasi- stationary behavior of ECG signals with respect to an individual. This lets to consider the ECG signal as a biometric characteristic and guarantees that different keys are released to different individuals. The performance of the proposed key generator is assessed using ECG signals from MIT-BIH database. Simulation results show a false accept rate (FAR) of 22.3% and a false reject rate (FRR) of 18.1%. The 128-bit key released by the generator proposed in this work can be used in several encryption algorithms. © 2009 IEEE.
@inproceedings{
title = {A wavelet-based 128-bit key generator using electrocardiogram signals},
type = {inproceedings},
year = {2009},
pages = {644-647},
websites = {http://ieeexplore.ieee.org/document/5236010/},
month = {8},
publisher = {IEEE},
id = {fdde3254-786e-3ea7-b243-b655856543af},
created = {2022-08-29T17:43:21.346Z},
file_attached = {false},
profile_id = {940dd160-7d67-3a5f-b9f8-935da0571367},
group_id = {92fccab2-8d44-33bc-b301-7b94bb18523c},
last_modified = {2022-08-29T17:43:21.346Z},
read = {false},
starred = {false},
authored = {false},
confirmed = {true},
hidden = {false},
private_publication = {false},
abstract = {In this paper, we present a wavelet-based 128-bit key generator using electrocardiogram (ECG) signals. The key generator comprises two independent stages, namely, enrollment and verification-generation. In the latter, an algorithm for determining the keys is also proposed. This work is based on the uniqueness and quasi- stationary behavior of ECG signals with respect to an individual. This lets to consider the ECG signal as a biometric characteristic and guarantees that different keys are released to different individuals. The performance of the proposed key generator is assessed using ECG signals from MIT-BIH database. Simulation results show a false accept rate (FAR) of 22.3% and a false reject rate (FRR) of 18.1%. The 128-bit key released by the generator proposed in this work can be used in several encryption algorithms. © 2009 IEEE.},
bibtype = {inproceedings},
author = {Garcia-Baleon, H. A. and Alarcon-Aquino, V. and Starostenko, O.},
doi = {10.1109/MWSCAS.2009.5236010},
booktitle = {2009 52nd IEEE International Midwest Symposium on Circuits and Systems}
}
Downloads: 0
{"_id":"ks2FLe6f9o5D8iSP5","bibbaseid":"garciabaleon-alarconaquino-starostenko-awaveletbased128bitkeygeneratorusingelectrocardiogramsignals-2009","downloads":0,"creationDate":"2018-11-16T03:10:01.140Z","title":"A wavelet-based 128-bit key generator using electrocardiogram signals","author_short":["Garcia-Baleon, H., A.","Alarcon-Aquino, V.","Starostenko, O."],"year":2009,"bibtype":"inproceedings","biburl":"https://bibbase.org/service/mendeley/940dd160-7d67-3a5f-b9f8-935da0571367","bibdata":{"title":"A wavelet-based 128-bit key generator using electrocardiogram signals","type":"inproceedings","year":"2009","pages":"644-647","websites":"http://ieeexplore.ieee.org/document/5236010/","month":"8","publisher":"IEEE","id":"fdde3254-786e-3ea7-b243-b655856543af","created":"2022-08-29T17:43:21.346Z","file_attached":false,"profile_id":"940dd160-7d67-3a5f-b9f8-935da0571367","group_id":"92fccab2-8d44-33bc-b301-7b94bb18523c","last_modified":"2022-08-29T17:43:21.346Z","read":false,"starred":false,"authored":false,"confirmed":"true","hidden":false,"private_publication":false,"abstract":"In this paper, we present a wavelet-based 128-bit key generator using electrocardiogram (ECG) signals. The key generator comprises two independent stages, namely, enrollment and verification-generation. In the latter, an algorithm for determining the keys is also proposed. This work is based on the uniqueness and quasi- stationary behavior of ECG signals with respect to an individual. This lets to consider the ECG signal as a biometric characteristic and guarantees that different keys are released to different individuals. The performance of the proposed key generator is assessed using ECG signals from MIT-BIH database. Simulation results show a false accept rate (FAR) of 22.3% and a false reject rate (FRR) of 18.1%. The 128-bit key released by the generator proposed in this work can be used in several encryption algorithms. © 2009 IEEE.","bibtype":"inproceedings","author":"Garcia-Baleon, H. A. and Alarcon-Aquino, V. and Starostenko, O.","doi":"10.1109/MWSCAS.2009.5236010","booktitle":"2009 52nd IEEE International Midwest Symposium on Circuits and Systems","bibtex":"@inproceedings{\n title = {A wavelet-based 128-bit key generator using electrocardiogram signals},\n type = {inproceedings},\n year = {2009},\n pages = {644-647},\n websites = {http://ieeexplore.ieee.org/document/5236010/},\n month = {8},\n publisher = {IEEE},\n id = {fdde3254-786e-3ea7-b243-b655856543af},\n created = {2022-08-29T17:43:21.346Z},\n file_attached = {false},\n profile_id = {940dd160-7d67-3a5f-b9f8-935da0571367},\n group_id = {92fccab2-8d44-33bc-b301-7b94bb18523c},\n last_modified = {2022-08-29T17:43:21.346Z},\n read = {false},\n starred = {false},\n authored = {false},\n confirmed = {true},\n hidden = {false},\n private_publication = {false},\n abstract = {In this paper, we present a wavelet-based 128-bit key generator using electrocardiogram (ECG) signals. The key generator comprises two independent stages, namely, enrollment and verification-generation. In the latter, an algorithm for determining the keys is also proposed. This work is based on the uniqueness and quasi- stationary behavior of ECG signals with respect to an individual. This lets to consider the ECG signal as a biometric characteristic and guarantees that different keys are released to different individuals. The performance of the proposed key generator is assessed using ECG signals from MIT-BIH database. Simulation results show a false accept rate (FAR) of 22.3% and a false reject rate (FRR) of 18.1%. The 128-bit key released by the generator proposed in this work can be used in several encryption algorithms. © 2009 IEEE.},\n bibtype = {inproceedings},\n author = {Garcia-Baleon, H. A. and Alarcon-Aquino, V. and Starostenko, O.},\n doi = {10.1109/MWSCAS.2009.5236010},\n booktitle = {2009 52nd IEEE International Midwest Symposium on Circuits and Systems}\n}","author_short":["Garcia-Baleon, H., A.","Alarcon-Aquino, V.","Starostenko, O."],"urls":{"Website":"http://ieeexplore.ieee.org/document/5236010/"},"biburl":"https://bibbase.org/service/mendeley/940dd160-7d67-3a5f-b9f8-935da0571367","bibbaseid":"garciabaleon-alarconaquino-starostenko-awaveletbased128bitkeygeneratorusingelectrocardiogramsignals-2009","role":"author","metadata":{"authorlinks":{}},"downloads":0},"search_terms":["wavelet","based","128","bit","key","generator","using","electrocardiogram","signals","garcia-baleon","alarcon-aquino","starostenko"],"keywords":[],"authorIDs":[],"dataSources":["uTykyhFv6T7J2dX6z","ya2CyA73rpZseyrZ8","nyWSrx2yzJEsoe49A","2252seNhipfTmjEBQ"]}