My First Biolab: A System for Hands-On Biology Experiments. Gome, G., Fein, Y., Waksberg, J., Maayan, Y., Grishko, A., Wald, I. Y., & Zuckerman, O. In Extended Abstracts of the 2019 CHI Conference on Human Factors in Computing Systems, of CHI EA '19, pages 1–6, New York, NY, USA, May, 2019. Association for Computing Machinery.
My First Biolab: A System for Hands-On Biology Experiments [link]Paper  doi  abstract   bibtex   
Biology labs routinely conduct direct experimentation with living organisms. However, most high-schools are not able to engage students in such experimentation due to multiple factors: sterility, cost of equipment, cost of skilled lab assistants, and difficulty measuring micro-scale processes. We present the design and implementation of My First Biolab (MFB), a lab in a box with a novel disposable fluidic vessel (experiment in a bag) using two sheets of Polyacrylamide-Polyethylene channeling liquids via paths created with a laser-cutter. The system implementation includes a 2D magnetic peristaltic pump, a spectral sensor, and a heat transfer plate. MFB is an affordable, safe, and sterile system for hands-on experimentation with live microorganisms. Our system supports temperature control, liquid circulation, measurement of optical density, and a web interface for remote control and monitoring. Our first experiment demonstrates the three phases of bacterial growth: initial lag phase, the rapid-growth log phase, and the stationary phase.
@inproceedings{gome_my_2019,
	address = {New York, NY, USA},
	series = {{CHI} {EA} '19},
	title = {My {First} {Biolab}: {A} {System} for {Hands}-{On} {Biology} {Experiments}},
	isbn = {978-1-4503-5971-9},
	shorttitle = {My {First} {Biolab}},
	url = {https://doi.org/10.1145/3290607.3313081},
	doi = {10.1145/3290607.3313081},
	abstract = {Biology labs routinely conduct direct experimentation with living organisms. However, most high-schools are not able to engage students in such experimentation due to multiple factors: sterility, cost of equipment, cost of skilled lab assistants, and difficulty measuring micro-scale processes. We present the design and implementation of My First Biolab (MFB), a lab in a box with a novel disposable fluidic vessel (experiment in a bag) using two sheets of Polyacrylamide-Polyethylene channeling liquids via paths created with a laser-cutter. The system implementation includes a 2D magnetic peristaltic pump, a spectral sensor, and a heat transfer plate. MFB is an affordable, safe, and sterile system for hands-on experimentation with live microorganisms. Our system supports temperature control, liquid circulation, measurement of optical density, and a web interface for remote control and monitoring. Our first experiment demonstrates the three phases of bacterial growth: initial lag phase, the rapid-growth log phase, and the stationary phase.},
	urldate = {2021-12-09},
	booktitle = {Extended {Abstracts} of the 2019 {CHI} {Conference} on {Human} {Factors} in {Computing} {Systems}},
	publisher = {Association for Computing Machinery},
	author = {Gome, Gilad and Fein, Yuval and Waksberg, Julian and Maayan, Yuval and Grishko, Andrey and Wald, Iddo Yehoshua and Zuckerman, Oren},
	month = may,
	year = {2019},
	keywords = {biology, design, education, human biology interaction (hbi), macrofluidics},
	pages = {1--6},
}

Downloads: 0