Doppler spectroscopy and D-alpha emission diagnostics for the C-2 FRC plasmaa). Gupta, D. K., Paganini, E., Balvis, A., Bonelli, L., Deng, B. H., Giammanco, F., Gornostaeva, O., Hayashi, R., Knapp, K., Marsili, P., McKenzie, M., Pousa-Hijos, R., Primavera, S., Schroeder, J., & Tuszewski, M. Review of Scientific Instruments, 81(10):10D737, October, 2010. 00003
Doppler spectroscopy and D-alpha emission diagnostics for the C-2 FRC plasmaa) [link]Paper  doi  abstract   bibtex   
Two Dopplerspectroscopydiagnostics with complementary capabilities are developed to measure the ion temperatures and velocities of FRC plasmas in the C-2 device. First, the multichord ion dopplerdiagnostic can simultaneously measure 15 chords of the plasma using an image intensified camera. Second, a single-chord fast-response ion Dopplerdiagnostic provides much higher faster time response by using a 16-channel photo-multiplier tube array. To study the neutral density of deuterium under different wall and plasma conditions, a highly sensitive eight-channel D-alpha diagnostic has been developed and calibrated for absolute radiance measurements. These spectroscopicdiagnostics capabilities, combined with other plasma diagnostics, are helping to understand and improve the field reversed configuration plasmas in the C-2 device.
@article{gupta_doppler_2010,
	title = {Doppler spectroscopy and {D}-alpha emission diagnostics for the {C}-2 {FRC} plasmaa)},
	volume = {81},
	issn = {0034-6748, 1089-7623},
	url = {http://scitation.aip.org/content/aip/journal/rsi/81/10/10.1063/1.3489971},
	doi = {10.1063/1.3489971},
	abstract = {Two Dopplerspectroscopydiagnostics with complementary capabilities are developed to measure the ion temperatures and velocities of FRC plasmas in the C-2 device. First, the multichord ion dopplerdiagnostic can simultaneously measure 15 chords of the plasma using an image intensified camera. Second, a single-chord fast-response ion Dopplerdiagnostic provides much higher faster time response by using a 16-channel photo-multiplier tube array. To study the neutral density of deuterium under different wall and plasma conditions, a highly sensitive eight-channel D-alpha diagnostic has been developed and calibrated for absolute radiance measurements. These spectroscopicdiagnostics capabilities, combined with other plasma diagnostics, are helping to understand and improve the field reversed configuration plasmas in the C-2 device.},
	number = {10},
	urldate = {2014-05-28TZ},
	journal = {Review of Scientific Instruments},
	author = {Gupta, Deepak K. and Paganini, E. and Balvis, A. and Bonelli, L. and Deng, B. H. and Giammanco, F. and Gornostaeva, O. and Hayashi, R. and Knapp, K. and Marsili, P. and McKenzie, M. and Pousa-Hijos, R. and Primavera, S. and Schroeder, J. and Tuszewski, M.},
	month = oct,
	year = {2010},
	note = {00003},
	keywords = {Cameras, DOPPLER EFFECT, PLASMA DIAGNOSTICS, Temperature measurement, plasma temperature},
	pages = {10D737}
}