Toward the Accurate Read-out of Quantum Dot Barcodes: Design of Deconvolution Algorithms and Assessment of Fluorescence Signals in Buffer. Lee, J. A., Hung, A., Mardyani, S., Rhee, A., Klostranec, J., Mu, Y., Li, D., & Chan, W. C. W. Advanced Materials, 19(20):3113–3118, 2007. _eprint: https://onlinelibrary.wiley.com/doi/pdf/10.1002/adma.200701955Paper Paper doi abstract bibtex Signal processing methods and constraints for discerning the fluorescence signals of the QD-barcodes are explored. QD-barcodes and their corresponding fluorescence spectra (see figure) require signal processing algorithms in order to be uniquely identified. Using these algorithms, we determined the number of available barcodes for use in biological detection. We also studied the impact of chemical constraints such as buffer and pH level on the barcode and read-out design.
@article{lee_toward_2007,
title = {Toward the {Accurate} {Read}-out of {Quantum} {Dot} {Barcodes}: {Design} of {Deconvolution} {Algorithms} and {Assessment} of {Fluorescence} {Signals} in {Buffer}},
volume = {19},
issn = {1521-4095},
shorttitle = {Toward the {Accurate} {Read}-out of {Quantum} {Dot} {Barcodes}},
url = {http://onlinelibrary.wiley.com/doi/abs/10.1002/adma.200701955},
doi = {10.1002/adma.200701955},
abstract = {Signal processing methods and constraints for discerning the fluorescence signals of the QD-barcodes are explored. QD-barcodes and their corresponding fluorescence spectra (see figure) require signal processing algorithms in order to be uniquely identified. Using these algorithms, we determined the number of available barcodes for use in biological detection. We also studied the impact of chemical constraints such as buffer and pH level on the barcode and read-out design.},
number = {20},
urldate = {2021-11-06},
journal = {Advanced Materials},
author = {Lee, J. A. and Hung, A. and Mardyani, S. and Rhee, A. and Klostranec, J. and Mu, Y. and Li, D. and Chan, W. C. W.},
year = {2007},
note = {\_eprint: https://onlinelibrary.wiley.com/doi/pdf/10.1002/adma.200701955},
keywords = {Biocompatible materials, Quantum dots, Sensors},
pages = {3113--3118},
file = {Full Text PDF:files/2211/Lee et al. - 2007 - Toward the Accurate Read-out of Quantum Dot Barcod.pdf:application/pdf;Snapshot:files/2212/adma.html:text/html},
url_Paper = {https://inbs.med.utoronto.ca/wp-content/uploads/2020/08/adma.200701955.pdf}
}
Downloads: 0
{"_id":"n93GjDHsNTLx9A6aJ","bibbaseid":"lee-hung-mardyani-rhee-klostranec-mu-li-chan-towardtheaccuratereadoutofquantumdotbarcodesdesignofdeconvolutionalgorithmsandassessmentoffluorescencesignalsinbuffer-2007","author_short":["Lee, J. A.","Hung, A.","Mardyani, S.","Rhee, A.","Klostranec, J.","Mu, Y.","Li, D.","Chan, W. C. W."],"bibdata":{"bibtype":"article","type":"article","title":"Toward the Accurate Read-out of Quantum Dot Barcodes: Design of Deconvolution Algorithms and Assessment of Fluorescence Signals in Buffer","volume":"19","issn":"1521-4095","shorttitle":"Toward the Accurate Read-out of Quantum Dot Barcodes","url":"http://onlinelibrary.wiley.com/doi/abs/10.1002/adma.200701955","doi":"10.1002/adma.200701955","abstract":"Signal processing methods and constraints for discerning the fluorescence signals of the QD-barcodes are explored. QD-barcodes and their corresponding fluorescence spectra (see figure) require signal processing algorithms in order to be uniquely identified. Using these algorithms, we determined the number of available barcodes for use in biological detection. We also studied the impact of chemical constraints such as buffer and pH level on the barcode and read-out design.","number":"20","urldate":"2021-11-06","journal":"Advanced Materials","author":[{"propositions":[],"lastnames":["Lee"],"firstnames":["J.","A."],"suffixes":[]},{"propositions":[],"lastnames":["Hung"],"firstnames":["A."],"suffixes":[]},{"propositions":[],"lastnames":["Mardyani"],"firstnames":["S."],"suffixes":[]},{"propositions":[],"lastnames":["Rhee"],"firstnames":["A."],"suffixes":[]},{"propositions":[],"lastnames":["Klostranec"],"firstnames":["J."],"suffixes":[]},{"propositions":[],"lastnames":["Mu"],"firstnames":["Y."],"suffixes":[]},{"propositions":[],"lastnames":["Li"],"firstnames":["D."],"suffixes":[]},{"propositions":[],"lastnames":["Chan"],"firstnames":["W.","C.","W."],"suffixes":[]}],"year":"2007","note":"_eprint: https://onlinelibrary.wiley.com/doi/pdf/10.1002/adma.200701955","keywords":"Biocompatible materials, Quantum dots, Sensors","pages":"3113–3118","file":"Full Text PDF:files/2211/Lee et al. - 2007 - Toward the Accurate Read-out of Quantum Dot Barcod.pdf:application/pdf;Snapshot:files/2212/adma.html:text/html","url_paper":"https://inbs.med.utoronto.ca/wp-content/uploads/2020/08/adma.200701955.pdf","bibtex":"@article{lee_toward_2007,\n\ttitle = {Toward the {Accurate} {Read}-out of {Quantum} {Dot} {Barcodes}: {Design} of {Deconvolution} {Algorithms} and {Assessment} of {Fluorescence} {Signals} in {Buffer}},\n\tvolume = {19},\n\tissn = {1521-4095},\n\tshorttitle = {Toward the {Accurate} {Read}-out of {Quantum} {Dot} {Barcodes}},\n\turl = {http://onlinelibrary.wiley.com/doi/abs/10.1002/adma.200701955},\n\tdoi = {10.1002/adma.200701955},\n\tabstract = {Signal processing methods and constraints for discerning the fluorescence signals of the QD-barcodes are explored. QD-barcodes and their corresponding fluorescence spectra (see figure) require signal processing algorithms in order to be uniquely identified. Using these algorithms, we determined the number of available barcodes for use in biological detection. We also studied the impact of chemical constraints such as buffer and pH level on the barcode and read-out design.},\n\tnumber = {20},\n\turldate = {2021-11-06},\n\tjournal = {Advanced Materials},\n\tauthor = {Lee, J. A. and Hung, A. and Mardyani, S. and Rhee, A. and Klostranec, J. and Mu, Y. and Li, D. and Chan, W. C. W.},\n\tyear = {2007},\n\tnote = {\\_eprint: https://onlinelibrary.wiley.com/doi/pdf/10.1002/adma.200701955},\n\tkeywords = {Biocompatible materials, Quantum dots, Sensors},\n\tpages = {3113--3118},\n\tfile = {Full Text PDF:files/2211/Lee et al. - 2007 - Toward the Accurate Read-out of Quantum Dot Barcod.pdf:application/pdf;Snapshot:files/2212/adma.html:text/html},\n\turl_Paper = {https://inbs.med.utoronto.ca/wp-content/uploads/2020/08/adma.200701955.pdf}\n}\n\n","author_short":["Lee, J. A.","Hung, A.","Mardyani, S.","Rhee, A.","Klostranec, J.","Mu, Y.","Li, D.","Chan, W. C. W."],"key":"lee_toward_2007","id":"lee_toward_2007","bibbaseid":"lee-hung-mardyani-rhee-klostranec-mu-li-chan-towardtheaccuratereadoutofquantumdotbarcodesdesignofdeconvolutionalgorithmsandassessmentoffluorescencesignalsinbuffer-2007","role":"author","urls":{"Paper":"http://onlinelibrary.wiley.com/doi/abs/10.1002/adma.200701955"," paper":"https://inbs.med.utoronto.ca/wp-content/uploads/2020/08/adma.200701955.pdf"},"keyword":["Biocompatible materials","Quantum dots","Sensors"],"metadata":{"authorlinks":{}},"html":""},"bibtype":"article","biburl":"https://inbslab.com//wp-content/uploads/2024/03/Chan-2024_03-14.txt","dataSources":["zb3p4i4Fd9wXynbkF","pF7M3AvRzd8m3Nc5t","BqtRhZTYdfYNLhWzp","sBWiDMMhfDHZnN93b","zkBeHFgTXc62hytzj","s3xwaPmQ7EjjEcMSb","5npqWkz6DHBZLyn3J","yc5dXnBwovT8YvCrt","nLduyq7S9B96QB8B5","JiWrSgLBTKbDLqiYi"],"keywords":["biocompatible materials","quantum dots","sensors"],"search_terms":["toward","accurate","read","out","quantum","dot","barcodes","design","deconvolution","algorithms","assessment","fluorescence","signals","buffer","lee","hung","mardyani","rhee","klostranec","mu","li","chan"],"title":"Toward the Accurate Read-out of Quantum Dot Barcodes: Design of Deconvolution Algorithms and Assessment of Fluorescence Signals in Buffer","year":2007}