Design of a Monitoring System for Electromagnetic Radiation Measurements. Mavromatis, F., Boursianis, A., Samaras, T., Koukourlis, C., & Sahalos, J., N. Technical Report 2008. Paper abstract bibtex The design of a monitoring system for measuring on a 24-hour basis the total electric field radiated from broadcasting and radiocommunications systems is presented. An omni-directional sensor antenna and the appropriate electronic circuits have been implemented. In the system various digital and analog peripherals are connected with a low-power, 8bit RISC microcontroller of Microchip, running at 10MHz. The measured data can be sending to a personal computer through a USB interface or through a GSM modem. Low cost electronics and high reliability of the system can deploy trustworthy electromagnetic radiation monitoring networks which will offer a security feeling to the public. The sensor's pattern, the response linearity and the frequency response have been tested and have shown the appropriate specifications.
@techreport{
title = {Design of a Monitoring System for Electromagnetic Radiation Measurements},
type = {techreport},
year = {2008},
source = {2008 XXIX General Assembly of the International Union of Radio Science, URSI GA},
keywords = {Broadband probes,electromagnetic fields,isotropic probes,monitoring systems},
id = {0a3f53e2-9f37-3fa0-a9b1-8ddec51d946f},
created = {2019-11-03T22:09:06.059Z},
file_attached = {true},
profile_id = {92581d97-724a-345d-9f14-9035bd05a74d},
last_modified = {2019-11-04T08:58:14.069Z},
read = {false},
starred = {false},
authored = {true},
confirmed = {false},
hidden = {false},
private_publication = {false},
abstract = {The design of a monitoring system for measuring on a 24-hour basis the total electric field radiated from broadcasting and radiocommunications systems is presented. An omni-directional sensor antenna and the appropriate electronic circuits have been implemented. In the system various digital and analog peripherals are connected with a low-power, 8bit RISC microcontroller of Microchip, running at 10MHz. The measured data can be sending to a personal computer through a USB interface or through a GSM modem. Low cost electronics and high reliability of the system can deploy trustworthy electromagnetic radiation monitoring networks which will offer a security feeling to the public. The sensor's pattern, the response linearity and the frequency response have been tested and have shown the appropriate specifications.},
bibtype = {techreport},
author = {Mavromatis, F and Boursianis, A and Samaras, Th and Koukourlis, Ch and Sahalos, J N}
}
Downloads: 0
{"_id":"5TbBejziL5taFj576","bibbaseid":"mavromatis-boursianis-samaras-koukourlis-sahalos-designofamonitoringsystemforelectromagneticradiationmeasurements-2008","authorIDs":["5c79a8c6b8dc37100000008d","5e26da9a42065ede01000072","5e2b0175df8a5dde01000010","5e63fffa24d8f2df01000143","MXQRo4H2RwQkYorcC","Tpr5e3hcPer3Xgd2e","YpMFuxLtvAoCt4MhS","ecZupPNfqf4vkmAen"],"author_short":["Mavromatis, F.","Boursianis, A.","Samaras, T.","Koukourlis, C.","Sahalos, J., N."],"bibdata":{"title":"Design of a Monitoring System for Electromagnetic Radiation Measurements","type":"techreport","year":"2008","source":"2008 XXIX General Assembly of the International Union of Radio Science, URSI GA","keywords":"Broadband probes,electromagnetic fields,isotropic probes,monitoring systems","id":"0a3f53e2-9f37-3fa0-a9b1-8ddec51d946f","created":"2019-11-03T22:09:06.059Z","file_attached":"true","profile_id":"92581d97-724a-345d-9f14-9035bd05a74d","last_modified":"2019-11-04T08:58:14.069Z","read":false,"starred":false,"authored":"true","confirmed":false,"hidden":false,"private_publication":false,"abstract":"The design of a monitoring system for measuring on a 24-hour basis the total electric field radiated from broadcasting and radiocommunications systems is presented. An omni-directional sensor antenna and the appropriate electronic circuits have been implemented. In the system various digital and analog peripherals are connected with a low-power, 8bit RISC microcontroller of Microchip, running at 10MHz. The measured data can be sending to a personal computer through a USB interface or through a GSM modem. Low cost electronics and high reliability of the system can deploy trustworthy electromagnetic radiation monitoring networks which will offer a security feeling to the public. The sensor's pattern, the response linearity and the frequency response have been tested and have shown the appropriate specifications.","bibtype":"techreport","author":"Mavromatis, F and Boursianis, A and Samaras, Th and Koukourlis, Ch and Sahalos, J N","bibtex":"@techreport{\n title = {Design of a Monitoring System for Electromagnetic Radiation Measurements},\n type = {techreport},\n year = {2008},\n source = {2008 XXIX General Assembly of the International Union of Radio Science, URSI GA},\n keywords = {Broadband probes,electromagnetic fields,isotropic probes,monitoring systems},\n id = {0a3f53e2-9f37-3fa0-a9b1-8ddec51d946f},\n created = {2019-11-03T22:09:06.059Z},\n file_attached = {true},\n profile_id = {92581d97-724a-345d-9f14-9035bd05a74d},\n last_modified = {2019-11-04T08:58:14.069Z},\n read = {false},\n starred = {false},\n authored = {true},\n confirmed = {false},\n hidden = {false},\n private_publication = {false},\n abstract = {The design of a monitoring system for measuring on a 24-hour basis the total electric field radiated from broadcasting and radiocommunications systems is presented. An omni-directional sensor antenna and the appropriate electronic circuits have been implemented. In the system various digital and analog peripherals are connected with a low-power, 8bit RISC microcontroller of Microchip, running at 10MHz. The measured data can be sending to a personal computer through a USB interface or through a GSM modem. Low cost electronics and high reliability of the system can deploy trustworthy electromagnetic radiation monitoring networks which will offer a security feeling to the public. The sensor's pattern, the response linearity and the frequency response have been tested and have shown the appropriate specifications.},\n bibtype = {techreport},\n author = {Mavromatis, F and Boursianis, A and Samaras, Th and Koukourlis, Ch and Sahalos, J N}\n}","author_short":["Mavromatis, F.","Boursianis, A.","Samaras, T.","Koukourlis, C.","Sahalos, J., N."],"urls":{"Paper":"https://bibbase.org/service/mendeley/92581d97-724a-345d-9f14-9035bd05a74d/file/10f6d3ad-f08e-062d-1e0e-9a8fc3752aea/FP1p6.pdf.pdf"},"biburl":"https://bibbase.org/service/mendeley/92581d97-724a-345d-9f14-9035bd05a74d","bibbaseid":"mavromatis-boursianis-samaras-koukourlis-sahalos-designofamonitoringsystemforelectromagneticradiationmeasurements-2008","role":"author","keyword":["Broadband probes","electromagnetic fields","isotropic probes","monitoring systems"],"metadata":{"authorlinks":{"boursianis, a":"https://bibbase.org/service/mendeley/92581d97-724a-345d-9f14-9035bd05a74d"}},"downloads":0},"bibtype":"techreport","creationDate":"2019-11-04T15:17:40.565Z","downloads":0,"keywords":["broadband probes","electromagnetic fields","isotropic probes","monitoring systems"],"search_terms":["design","monitoring","system","electromagnetic","radiation","measurements","mavromatis","boursianis","samaras","koukourlis","sahalos"],"title":"Design of a Monitoring System for Electromagnetic Radiation Measurements","year":2008,"biburl":"https://bibbase.org/service/mendeley/92581d97-724a-345d-9f14-9035bd05a74d","dataSources":["bmjNqkJHSoBWDZhXC","ya2CyA73rpZseyrZ8","2252seNhipfTmjEBQ"]}