High-accuracy mass determination of neutron-rich rubidium and strontium isotopes. Raimbault-Hartmann, H., Audi, G., Beck, D., Bollen, G., De Saint Simon, M., Kluge, H., J., König, M., Moore, R., B., Schwarz, S., Savard, G., & Szerypo, J. Nuclear Physics A, 706(1-2):3-14, North-Holland, 7, 2002.
doi  abstract   bibtex   
The Penning trap mass spectrometer ISOLTRAP, installed at the on-line isotope separator ISOLDE at CERN, has been used to measure atomic masses of 88,89,90m,91,92,93,94Rb and 91,92,93,94,95Sr. Using a resolving power of R ≈ 1 million a mass accuracy of typically 10 keV was achieved for all nuclides. Discrepancies with older data are analyzed and discussed, leading to corrections to those data. Together with the present ISOLTRAP data these corrected data have been used in a general mass adjustment. © 2002 Elsevier Science B.V. All rights reserved.
@article{
 title = {High-accuracy mass determination of neutron-rich rubidium and strontium isotopes},
 type = {article},
 year = {2002},
 keywords = {Atomic masses88,89,90,91,92,93,94,95Sr,Least-squares adjustment of data,Measured masses,On-line mass spectrometry,Penning trap},
 pages = {3-14},
 volume = {706},
 month = {7},
 publisher = {North-Holland},
 day = {29},
 id = {2c7131e1-f750-36e1-b45c-b8873fdd6aa9},
 created = {2023-07-31T18:36:29.748Z},
 accessed = {2022-01-20},
 file_attached = {false},
 profile_id = {4aed738b-137b-3d29-9e3a-9ef895581cc9},
 group_id = {033577ea-f905-3a88-a6d2-1db6bc10e2f3},
 last_modified = {2023-07-31T18:36:29.748Z},
 read = {false},
 starred = {false},
 authored = {false},
 confirmed = {false},
 hidden = {false},
 private_publication = {false},
 abstract = {The Penning trap mass spectrometer ISOLTRAP, installed at the on-line isotope separator ISOLDE at CERN, has been used to measure atomic masses of 88,89,90m,91,92,93,94Rb and 91,92,93,94,95Sr. Using a resolving power of R ≈ 1 million a mass accuracy of typically 10 keV was achieved for all nuclides. Discrepancies with older data are analyzed and discussed, leading to corrections to those data. Together with the present ISOLTRAP data these corrected data have been used in a general mass adjustment. © 2002 Elsevier Science B.V. All rights reserved.},
 bibtype = {article},
 author = {Raimbault-Hartmann, H. and Audi, G. and Beck, D. and Bollen, G. and De Saint Simon, M. and Kluge, H. J. and König, M. and Moore, R. B. and Schwarz, S. and Savard, G. and Szerypo, J.},
 doi = {10.1016/S0375-9474(02)00863-1},
 journal = {Nuclear Physics A},
 number = {1-2}
}

Downloads: 0