A cylindrical Penning trap for capture, mass selective cooling, and bunching of radioactive ion beams. Raimbault-Hartmann, H., Beck, D., Bollen, G., König, M., Kluge, H., J., Schark, E., Stein, J., Schwarz, S., & Szerypo, J. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 126(1-4):378-382, North-Holland, 4, 1997.
doi  abstract   bibtex   1 download  
A Penning trap ion accumulator, cooler, and buncher for low-energy ion beams has been developed for the ISOLTRAP mass spectrometer at ISOLDE/CERN. A cylindrical electrode configuration is used for the creation of a nested trapping potential This is required for efficient accumulation of externally produced ions and for high-mass selectivity by buffer gas cooling. The design goal of a mass resolving power of about 1 × 105 has been achieved. Isobar separation has been demonstrated for radioactive rare-earth ion beams delivered by the ISOLDE on-line mass separator.
@article{
 title = {A cylindrical Penning trap for capture, mass selective cooling, and bunching of radioactive ion beams},
 type = {article},
 year = {1997},
 keywords = {Ion accumulation,Ion cooling,Mass separation,Penning trap},
 pages = {378-382},
 volume = {126},
 month = {4},
 publisher = {North-Holland},
 day = {4},
 id = {71973bc5-19b0-3544-ba29-559d277d37c5},
 created = {2023-07-31T18:36:43.128Z},
 accessed = {2022-01-20},
 file_attached = {false},
 profile_id = {4aed738b-137b-3d29-9e3a-9ef895581cc9},
 group_id = {033577ea-f905-3a88-a6d2-1db6bc10e2f3},
 last_modified = {2023-07-31T18:36:43.128Z},
 read = {false},
 starred = {false},
 authored = {false},
 confirmed = {false},
 hidden = {false},
 private_publication = {false},
 abstract = {A Penning trap ion accumulator, cooler, and buncher for low-energy ion beams has been developed for the ISOLTRAP mass spectrometer at ISOLDE/CERN. A cylindrical electrode configuration is used for the creation of a nested trapping potential This is required for efficient accumulation of externally produced ions and for high-mass selectivity by buffer gas cooling. The design goal of a mass resolving power of about 1 × 105 has been achieved. Isobar separation has been demonstrated for radioactive rare-earth ion beams delivered by the ISOLDE on-line mass separator.},
 bibtype = {article},
 author = {Raimbault-Hartmann, H. and Beck, D. and Bollen, G. and König, M. and Kluge, H. J. and Schark, E. and Stein, J. and Schwarz, S. and Szerypo, J.},
 doi = {10.1016/S0168-583X(96)01067-1},
 journal = {Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms},
 number = {1-4}
}