Multiplexed microfluidic fluorescence immunoassay with photodiode array signal acquisition for sub-minute and point-of-need detection of mycotoxins. Soares, R. R. G., Santos, D. R., Pinto, I. F., Azevedo, A. M., Raquel Aires-Barros, M., Chu, V., & Conde, J. P. LAB ON A CHIP, 18(11):1569-1580, JUN 7, 2018. doi abstract bibtex Portable, rapid, cost effective and simple analytical tools are in increasing demand to facilitate the routine monitoring of target chemical/biological compounds at the point-of-need. Such devices are highly relevant within the context of food safety, particularly concerning the screening of highly toxic and strictly regulated mycotoxins. To achieve ultrarapid detection of mycotoxins, namely aflatoxin B1, ochratoxin A and deoxynivalenol, at the point-of-need, a novel multiplexed bead-based microfluidic competitive immunosensor, coupled with an array of a-Si:H thin-film photodiodes for integrated fluorescence signal acquisition, is reported. Simultaneously measuring the initial binding rate for each analyte of the sample under analysis against an internal reference, this device provided limits of detection below 1 ng mL(-1) for all mycotoxins in a single-step assay and within 1 minute after mixing the sample under analysis with a fluorescent conjugate. The compatibility of the device with the analysis of mycotoxins spiked in corn samples was further demonstrated after performing a sample preparation procedure based on aqueous two-phase extraction. The short times of analysis and sensitivities in the low ng mL(-1) range make these devices potentially competitive with the lateral flow devices that are currently the standard for this application. Furthermore, this device architecture and concept is amenable of being expanded to other analytes in food safety, biomedical and other applications.
@article{ ISI:000437658200007,
Author = {Soares, Ruben R. G. and Santos, Denis R. and Pinto, Ines F. and Azevedo,
Ana M. and Raquel Aires-Barros, M. and Chu, Virginia and Conde, Joao P.},
Title = {{Multiplexed microfluidic fluorescence immunoassay with photodiode array
signal acquisition for sub-minute and point-of-need detection of
mycotoxins}},
Journal = {{LAB ON A CHIP}},
Year = {{2018}},
Volume = {{18}},
Number = {{11}},
Pages = {{1569-1580}},
Month = {{JUN 7}},
Abstract = {{Portable, rapid, cost effective and simple analytical tools are in
increasing demand to facilitate the routine monitoring of target
chemical/biological compounds at the point-of-need. Such devices are
highly relevant within the context of food safety, particularly
concerning the screening of highly toxic and strictly regulated
mycotoxins. To achieve ultrarapid detection of mycotoxins, namely
aflatoxin B1, ochratoxin A and deoxynivalenol, at the point-of-need, a
novel multiplexed bead-based microfluidic competitive immunosensor,
coupled with an array of a-Si:H thin-film photodiodes for integrated
fluorescence signal acquisition, is reported. Simultaneously measuring
the initial binding rate for each analyte of the sample under analysis
against an internal reference, this device provided limits of detection
below 1 ng mL(-1) for all mycotoxins in a single-step assay and within 1
minute after mixing the sample under analysis with a fluorescent
conjugate. The compatibility of the device with the analysis of
mycotoxins spiked in corn samples was further demonstrated after
performing a sample preparation procedure based on aqueous two-phase
extraction. The short times of analysis and sensitivities in the low ng
mL(-1) range make these devices potentially competitive with the lateral
flow devices that are currently the standard for this application.
Furthermore, this device architecture and concept is amenable of being
expanded to other analytes in food safety, biomedical and other
applications.}},
DOI = {{10.1039/c8lc00259b}},
ISSN = {{1473-0197}},
EISSN = {{1473-0189}},
ResearcherID-Numbers = {{Soares, Ruben Rafael Goncalves/H-9580-2019
Conde, Joao Pedro/F-8533-2012
Azevedo, Ana Margarida/A-2985-2011
Santos, Denis R./F-4015-2018
Chu, Virginia/I-6048-2014
}},
ORCID-Numbers = {{Soares, Ruben Rafael Goncalves/0000-0001-5958-5232
Conde, Joao Pedro/0000-0002-5677-3024
Azevedo, Ana Margarida/0000-0001-5659-466X
Santos, Denis R./0000-0001-7992-9602
Chu, Virginia/0000-0002-5306-4409
Pinto, Ines/0000-0002-9714-4742}},
Unique-ID = {{ISI:000437658200007}},
}
Downloads: 0
{"_id":"6k2Bx8gMcnAjndj8t","bibbaseid":"soares-santos-pinto-azevedo-raquelairesbarros-chu-conde-multiplexedmicrofluidicfluorescenceimmunoassaywithphotodiodearraysignalacquisitionforsubminuteandpointofneeddetectionofmycotoxins-2018","authorIDs":[],"author_short":["Soares, R. R. G.","Santos, D. R.","Pinto, I. F.","Azevedo, A. M.","Raquel Aires-Barros, M.","Chu, V.","Conde, J. P."],"bibdata":{"bibtype":"article","type":"article","author":[{"propositions":[],"lastnames":["Soares"],"firstnames":["Ruben","R.","G."],"suffixes":[]},{"propositions":[],"lastnames":["Santos"],"firstnames":["Denis","R."],"suffixes":[]},{"propositions":[],"lastnames":["Pinto"],"firstnames":["Ines","F."],"suffixes":[]},{"propositions":[],"lastnames":["Azevedo"],"firstnames":["Ana","M."],"suffixes":[]},{"propositions":[],"lastnames":["Raquel","Aires-Barros"],"firstnames":["M."],"suffixes":[]},{"propositions":[],"lastnames":["Chu"],"firstnames":["Virginia"],"suffixes":[]},{"propositions":[],"lastnames":["Conde"],"firstnames":["Joao","P."],"suffixes":[]}],"title":"Multiplexed microfluidic fluorescence immunoassay with photodiode array signal acquisition for sub-minute and point-of-need detection of mycotoxins","journal":"LAB ON A CHIP","year":"2018","volume":"18","number":"11","pages":"1569-1580","month":"JUN 7","abstract":"Portable, rapid, cost effective and simple analytical tools are in increasing demand to facilitate the routine monitoring of target chemical/biological compounds at the point-of-need. Such devices are highly relevant within the context of food safety, particularly concerning the screening of highly toxic and strictly regulated mycotoxins. To achieve ultrarapid detection of mycotoxins, namely aflatoxin B1, ochratoxin A and deoxynivalenol, at the point-of-need, a novel multiplexed bead-based microfluidic competitive immunosensor, coupled with an array of a-Si:H thin-film photodiodes for integrated fluorescence signal acquisition, is reported. Simultaneously measuring the initial binding rate for each analyte of the sample under analysis against an internal reference, this device provided limits of detection below 1 ng mL(-1) for all mycotoxins in a single-step assay and within 1 minute after mixing the sample under analysis with a fluorescent conjugate. The compatibility of the device with the analysis of mycotoxins spiked in corn samples was further demonstrated after performing a sample preparation procedure based on aqueous two-phase extraction. The short times of analysis and sensitivities in the low ng mL(-1) range make these devices potentially competitive with the lateral flow devices that are currently the standard for this application. Furthermore, this device architecture and concept is amenable of being expanded to other analytes in food safety, biomedical and other applications.","doi":"10.1039/c8lc00259b","issn":"1473-0197","eissn":"1473-0189","researcherid-numbers":"Soares, Ruben Rafael Goncalves/H-9580-2019 Conde, Joao Pedro/F-8533-2012 Azevedo, Ana Margarida/A-2985-2011 Santos, Denis R./F-4015-2018 Chu, Virginia/I-6048-2014 ","orcid-numbers":"Soares, Ruben Rafael Goncalves/0000-0001-5958-5232 Conde, Joao Pedro/0000-0002-5677-3024 Azevedo, Ana Margarida/0000-0001-5659-466X Santos, Denis R./0000-0001-7992-9602 Chu, Virginia/0000-0002-5306-4409 Pinto, Ines/0000-0002-9714-4742","unique-id":"ISI:000437658200007","bibtex":"@article{ ISI:000437658200007,\nAuthor = {Soares, Ruben R. G. and Santos, Denis R. and Pinto, Ines F. and Azevedo,\n Ana M. and Raquel Aires-Barros, M. and Chu, Virginia and Conde, Joao P.},\nTitle = {{Multiplexed microfluidic fluorescence immunoassay with photodiode array\n signal acquisition for sub-minute and point-of-need detection of\n mycotoxins}},\nJournal = {{LAB ON A CHIP}},\nYear = {{2018}},\nVolume = {{18}},\nNumber = {{11}},\nPages = {{1569-1580}},\nMonth = {{JUN 7}},\nAbstract = {{Portable, rapid, cost effective and simple analytical tools are in\n increasing demand to facilitate the routine monitoring of target\n chemical/biological compounds at the point-of-need. Such devices are\n highly relevant within the context of food safety, particularly\n concerning the screening of highly toxic and strictly regulated\n mycotoxins. To achieve ultrarapid detection of mycotoxins, namely\n aflatoxin B1, ochratoxin A and deoxynivalenol, at the point-of-need, a\n novel multiplexed bead-based microfluidic competitive immunosensor,\n coupled with an array of a-Si:H thin-film photodiodes for integrated\n fluorescence signal acquisition, is reported. Simultaneously measuring\n the initial binding rate for each analyte of the sample under analysis\n against an internal reference, this device provided limits of detection\n below 1 ng mL(-1) for all mycotoxins in a single-step assay and within 1\n minute after mixing the sample under analysis with a fluorescent\n conjugate. The compatibility of the device with the analysis of\n mycotoxins spiked in corn samples was further demonstrated after\n performing a sample preparation procedure based on aqueous two-phase\n extraction. The short times of analysis and sensitivities in the low ng\n mL(-1) range make these devices potentially competitive with the lateral\n flow devices that are currently the standard for this application.\n Furthermore, this device architecture and concept is amenable of being\n expanded to other analytes in food safety, biomedical and other\n applications.}},\nDOI = {{10.1039/c8lc00259b}},\nISSN = {{1473-0197}},\nEISSN = {{1473-0189}},\nResearcherID-Numbers = {{Soares, Ruben Rafael Goncalves/H-9580-2019\n Conde, Joao Pedro/F-8533-2012\n Azevedo, Ana Margarida/A-2985-2011\n Santos, Denis R./F-4015-2018\n Chu, Virginia/I-6048-2014\n }},\nORCID-Numbers = {{Soares, Ruben Rafael Goncalves/0000-0001-5958-5232\n Conde, Joao Pedro/0000-0002-5677-3024\n Azevedo, Ana Margarida/0000-0001-5659-466X\n Santos, Denis R./0000-0001-7992-9602\n Chu, Virginia/0000-0002-5306-4409\n Pinto, Ines/0000-0002-9714-4742}},\nUnique-ID = {{ISI:000437658200007}},\n}\n\n","author_short":["Soares, R. R. G.","Santos, D. R.","Pinto, I. F.","Azevedo, A. M.","Raquel Aires-Barros, M.","Chu, V.","Conde, J. P."],"key":"ISI:000437658200007","id":"ISI:000437658200007","bibbaseid":"soares-santos-pinto-azevedo-raquelairesbarros-chu-conde-multiplexedmicrofluidicfluorescenceimmunoassaywithphotodiodearraysignalacquisitionforsubminuteandpointofneeddetectionofmycotoxins-2018","role":"author","urls":{},"downloads":0},"bibtype":"article","biburl":"http://nanotec.cnr.it/data/nanotec/nanotec-full.bib","creationDate":"2020-04-21T16:04:30.340Z","downloads":0,"keywords":[],"search_terms":["multiplexed","microfluidic","fluorescence","immunoassay","photodiode","array","signal","acquisition","sub","minute","point","need","detection","mycotoxins","soares","santos","pinto","azevedo","raquel aires-barros","chu","conde"],"title":"Multiplexed microfluidic fluorescence immunoassay with photodiode array signal acquisition for sub-minute and point-of-need detection of mycotoxins","year":2018,"dataSources":["ZTEbWc6bW5f9DTsjF"]}