A short note on how to convert a conventional analytical TEM into an analytical low voltage TEM. Stöger-Pollach, M. Ultramicroscopy. 00000Paper doi abstract bibtex The present work is a short note on the performance of a conventional transmission electron microscope (TEM) being operated at very low beam energies (below 20 keV). We discuss the high tension stability and resolving power of this uncorrected TEM. We find out that the theoretical lens performance can nearly be achieved in practice. We also demonstrate that electron energy loss spectra can be recorded at these low beam energies with standard equipment. The signal-to-noise ratio is sufficiently good for further data treatment like multiple scattering deconvolution and Kramers–Kronig analysis.
@article{stoger-pollach_short_nodate,
title = {A short note on how to convert a conventional analytical {TEM} into an analytical low voltage {TEM}},
issn = {0304-3991},
url = {http://www.sciencedirect.com/science/article/pii/S0304399114000187},
doi = {10.1016/j.ultramic.2014.01.008},
abstract = {The present work is a short note on the performance of a conventional transmission electron microscope (TEM) being operated at very low beam energies (below 20 keV). We discuss the high tension stability and resolving power of this uncorrected TEM. We find out that the theoretical lens performance can nearly be achieved in practice. We also demonstrate that electron energy loss spectra can be recorded at these low beam energies with standard equipment. The signal-to-noise ratio is sufficiently good for further data treatment like multiple scattering deconvolution and Kramers–Kronig analysis.},
urldate = {2014-02-03},
journal = {Ultramicroscopy},
author = {Stöger-Pollach, M.},
note = {00000},
keywords = {Electron conversion, Low voltage EELS, Low voltage TEM, Resolution},
}
Downloads: 0
{"_id":"NhiarHZFPyEtnPatP","bibbaseid":"stgerpollach-ashortnoteonhowtoconvertaconventionalanalyticaltemintoananalyticallowvoltagetem","author_short":["Stöger-Pollach, M."],"bibdata":{"bibtype":"article","type":"article","title":"A short note on how to convert a conventional analytical TEM into an analytical low voltage TEM","issn":"0304-3991","url":"http://www.sciencedirect.com/science/article/pii/S0304399114000187","doi":"10.1016/j.ultramic.2014.01.008","abstract":"The present work is a short note on the performance of a conventional transmission electron microscope (TEM) being operated at very low beam energies (below 20 keV). We discuss the high tension stability and resolving power of this uncorrected TEM. We find out that the theoretical lens performance can nearly be achieved in practice. We also demonstrate that electron energy loss spectra can be recorded at these low beam energies with standard equipment. The signal-to-noise ratio is sufficiently good for further data treatment like multiple scattering deconvolution and Kramers–Kronig analysis.","urldate":"2014-02-03","journal":"Ultramicroscopy","author":[{"propositions":[],"lastnames":["Stöger-Pollach"],"firstnames":["M."],"suffixes":[]}],"note":"00000","keywords":"Electron conversion, Low voltage EELS, Low voltage TEM, Resolution","bibtex":"@article{stoger-pollach_short_nodate,\n\ttitle = {A short note on how to convert a conventional analytical {TEM} into an analytical low voltage {TEM}},\n\tissn = {0304-3991},\n\turl = {http://www.sciencedirect.com/science/article/pii/S0304399114000187},\n\tdoi = {10.1016/j.ultramic.2014.01.008},\n\tabstract = {The present work is a short note on the performance of a conventional transmission electron microscope (TEM) being operated at very low beam energies (below 20 keV). We discuss the high tension stability and resolving power of this uncorrected TEM. We find out that the theoretical lens performance can nearly be achieved in practice. We also demonstrate that electron energy loss spectra can be recorded at these low beam energies with standard equipment. The signal-to-noise ratio is sufficiently good for further data treatment like multiple scattering deconvolution and Kramers–Kronig analysis.},\n\turldate = {2014-02-03},\n\tjournal = {Ultramicroscopy},\n\tauthor = {Stöger-Pollach, M.},\n\tnote = {00000},\n\tkeywords = {Electron conversion, Low voltage EELS, Low voltage TEM, Resolution},\n}\n\n","author_short":["Stöger-Pollach, M."],"key":"stoger-pollach_short_nodate","id":"stoger-pollach_short_nodate","bibbaseid":"stgerpollach-ashortnoteonhowtoconvertaconventionalanalyticaltemintoananalyticallowvoltagetem","role":"author","urls":{"Paper":"http://www.sciencedirect.com/science/article/pii/S0304399114000187"},"keyword":["Electron conversion","Low voltage EELS","Low voltage TEM","Resolution"],"metadata":{"authorlinks":{}}},"bibtype":"article","biburl":"https://bibbase.org/zotero/ricounet67","dataSources":["rx3H6duFmTt3xD5yy"],"keywords":["electron conversion","low voltage eels","low voltage tem","resolution"],"search_terms":["short","note","convert","conventional","analytical","tem","analytical","low","voltage","tem","stöger-pollach"],"title":"A short note on how to convert a conventional analytical TEM into an analytical low voltage TEM","year":null}