Intrabody Communication in Biotelemetry. Vasic, Z. L., Krois, I., & Cifrek, M. In ANNUAL 2015 OF THE CROATIAN ACADEMY OF ENGINEERING, of Annual of the Croatian Academy of Engineering, pages 301+. CROATIAN ACADEMY ENGINEERING, KACICEVA 28, ZAGREB, 10000, CROATIA, 2016. doi abstract bibtex Biotelemetry is remote monitoring, measuring and recording of a living organism's function, activity or condition. Network of sensor nodes placed on or implanted inside the body of a subject is called Body Area Network (BAN). In this work we will describe the principles of a wireless body area network which uses the human body as a transmission medium, namely intrabody communication (IBC). We will describe the limitations set on the IBC systems, describe dielectric properties of the human body as a transmission medium, specify different ways of transmitting signals through the human body and compare characteristics of the IBC systems found in the literature.
@incollection{WOS:000379450000017,
abstract = {Biotelemetry is remote monitoring, measuring and recording of a living
organism's function, activity or condition. Network of sensor nodes
placed on or implanted inside the body of a subject is called Body Area
Network (BAN). In this work we will describe the principles of a
wireless body area network which uses the human body as a transmission
medium, namely intrabody communication (IBC). We will describe the
limitations set on the IBC systems, describe dielectric properties of
the human body as a transmission medium, specify different ways of
transmitting signals through the human body and compare characteristics
of the IBC systems found in the literature.},
address = {KACICEVA 28, ZAGREB, 10000, CROATIA},
author = {Vasic, Zeljka Lucev and Krois, Igor and Cifrek, Mario},
booktitle = {ANNUAL 2015 OF THE CROATIAN ACADEMY OF ENGINEERING},
doi = {10.1007/978-3-642-15687-8\_18},
editor = {Androcec, V},
issn = {1332-3482},
keywords = {Biotelemetry; intrabody communication (IBC); capac},
pages = {301+},
publisher = {CROATIAN ACADEMY ENGINEERING},
series = {Annual of the Croatian Academy of Engineering},
title = {{Intrabody Communication in Biotelemetry}},
type = {Article; Book Chapter},
year = {2016}
}
Downloads: 0
{"_id":"EBqAbngY7XE9J6hia","bibbaseid":"vasic-krois-cifrek-intrabodycommunicationinbiotelemetry-2016","author_short":["Vasic, Z. L.","Krois, I.","Cifrek, M."],"bibdata":{"bibtype":"incollection","type":"Article; Book Chapter","abstract":"Biotelemetry is remote monitoring, measuring and recording of a living organism's function, activity or condition. Network of sensor nodes placed on or implanted inside the body of a subject is called Body Area Network (BAN). In this work we will describe the principles of a wireless body area network which uses the human body as a transmission medium, namely intrabody communication (IBC). We will describe the limitations set on the IBC systems, describe dielectric properties of the human body as a transmission medium, specify different ways of transmitting signals through the human body and compare characteristics of the IBC systems found in the literature.","address":"KACICEVA 28, ZAGREB, 10000, CROATIA","author":[{"propositions":[],"lastnames":["Vasic"],"firstnames":["Zeljka","Lucev"],"suffixes":[]},{"propositions":[],"lastnames":["Krois"],"firstnames":["Igor"],"suffixes":[]},{"propositions":[],"lastnames":["Cifrek"],"firstnames":["Mario"],"suffixes":[]}],"booktitle":"ANNUAL 2015 OF THE CROATIAN ACADEMY OF ENGINEERING","doi":"10.1007/978-3-642-15687-8_18","editor":[{"propositions":[],"lastnames":["Androcec"],"firstnames":["V"],"suffixes":[]}],"issn":"1332-3482","keywords":"Biotelemetry; intrabody communication (IBC); capac","pages":"301+","publisher":"CROATIAN ACADEMY ENGINEERING","series":"Annual of the Croatian Academy of Engineering","title":"Intrabody Communication in Biotelemetry","year":"2016","bibtex":"@incollection{WOS:000379450000017,\nabstract = {Biotelemetry is remote monitoring, measuring and recording of a living\norganism's function, activity or condition. Network of sensor nodes\nplaced on or implanted inside the body of a subject is called Body Area\nNetwork (BAN). In this work we will describe the principles of a\nwireless body area network which uses the human body as a transmission\nmedium, namely intrabody communication (IBC). We will describe the\nlimitations set on the IBC systems, describe dielectric properties of\nthe human body as a transmission medium, specify different ways of\ntransmitting signals through the human body and compare characteristics\nof the IBC systems found in the literature.},\naddress = {KACICEVA 28, ZAGREB, 10000, CROATIA},\nauthor = {Vasic, Zeljka Lucev and Krois, Igor and Cifrek, Mario},\nbooktitle = {ANNUAL 2015 OF THE CROATIAN ACADEMY OF ENGINEERING},\ndoi = {10.1007/978-3-642-15687-8\\_18},\neditor = {Androcec, V},\nissn = {1332-3482},\nkeywords = {Biotelemetry; intrabody communication (IBC); capac},\npages = {301+},\npublisher = {CROATIAN ACADEMY ENGINEERING},\nseries = {Annual of the Croatian Academy of Engineering},\ntitle = {{Intrabody Communication in Biotelemetry}},\ntype = {Article; Book Chapter},\nyear = {2016}\n}\n","author_short":["Vasic, Z. L.","Krois, I.","Cifrek, M."],"editor_short":["Androcec, V"],"key":"WOS:000379450000017","id":"WOS:000379450000017","bibbaseid":"vasic-krois-cifrek-intrabodycommunicationinbiotelemetry-2016","role":"author","urls":{},"keyword":["Biotelemetry; intrabody communication (IBC); capac"],"metadata":{"authorlinks":{}}},"bibtype":"incollection","biburl":"https://bibbase.org/f/rTKwnBhyGKSSptYtt/My Collection.bib","dataSources":["DY3AeP9t2QujfB78L","MpTxM7aR49zFotABd"],"keywords":["biotelemetry; intrabody communication (ibc); capac"],"search_terms":["intrabody","communication","biotelemetry","vasic","krois","cifrek"],"title":"Intrabody Communication in Biotelemetry","year":2016}